POWERHEAD LEDS
Powerhead LED
Round LED
Long LED
OFF
ON/RED/
ON/RED/
STEADY
STEADY
ON/RED/
ON/RED/
FLASHING
FLASHING
ON/BLUE/
FLASHING
ON/PURPLE/
FLASHING
ON/RED/
FLASHING
ON/RED/
OFF
FLASHING
ON/RED/
OFF
STEADY
ON/PURPLE/
ON/PURPLE/
STEADY
STEADY
ON/BLUE/
OFF
FLASHING
ON/PURPLE/
ON/PURPLE/
FLASHING
FLASHING
ON/GREEN
ON/GREEN
STEADY
STEADY
ON/GREEN
ON/GREEN
FLASHING
FLASHING
ON/YELLOW
ON/YELLOW
FLASHING
FLASHING
ON/RED TO YELLOW
ON/RED TO YELLOW
FLASHING
FLASHING
ON/WHITE STEADY ON/WHITE STEADY Battery Backup in Operation
LED DISPLAY UNDER NORMAL OPERATING CONDITIONS
Standard Models
NO LED DISPLAY
Possible Problem
Normal operation.
OFF
No response from unit.
Limits NOT set properly.
Program error.
Component failure.
OFF
Remote NOT programmed.
OFF
Remote NOT programmed.
Safe-T-Beam® physical obstruction.
OFF
Safe-T-Beam® signal interference.
Door contact in UP or DOWN travel.
Door component failure detected.
Thermal cutout.
Component error.
Door will not open.
Radio receiver error.
Battery Backup Troubleshooting LEDs
OK=Charged, Battery Backup
Discharging, Battery Backup
Charging, Battery Backup
Dead Battery, Battery Backup
None required.
Check power supply.
Contact a trained door system professional.
Re-program limits, see pages 6-7.
Unplug unit, wait 5 seconds, plug in.
Contact a trained door system technician.
Program remote, see page 9.
Program remote, see page 9.
Remote obstruction, recheck unit.
Check alignment of Safe-T-Beam® pair and
nearest other Safe-T-Beam® pair, see page 18.
Remove obstruction.
Check door spring, track, rollers, hinges and
fixtures.
DO NOT unplug unit.
Wait until LED clears before operating.
Contact a trained door system technician.
Check Sure-Lock™. Sure-Lock™ should be OFF for
normal operation (see page 6).
Unplug the unit. Wait 5 seconds and plug the unit
back in. If problems persist, contact a trained door
system technician.
None Required
Power is out. Battery in use.
None Required
Allow to charge 48 hours. If charging fails,
Replace Battery.
No Fault. Courtesy light while in battery
backup mode. Light will turn off after 4
minutes.
Battery Back-up Models
BOTH LEDs = STEADY GREEN
Solution