  Auxiliary modules
4.1
4.
4.1.1
4.1.2
174
QC-PDS
HARDWARE
Ref.2003
· 140 ·

Mains Filters

I n o r d e r t o c o m p l y w i t h E u r o p e a n D i r e c t i v e 2 0 1 4 / 3 0 / E U o n
Electromagnetic Compatibility, it is mandatory to insert a mains filter.
Particularly, the standard IEC 61800-3 for category C3 and the standard
IEC 61800-5-2 for immunity.
The main filters included in the FAGOR catalog and required for QC-PDS
systems are the MAIN FILTER A-A.
These are installed between mains and the QC-PDS system and whose
main purpose is to reduce conducted disturbances caused by the drive
down to the levels indicated under the aforementioned standard and, at
the same time, make it immune to transient over-voltage like bursts or
voltage pulses.
Outside appearance
MAIN FILTER 42A-A
MAIN FILTER 75A-A
F. H4/1
Mains filters. Outside appearance.
Technical data
Mains filters. Technical data.
T. H4/1
MAIN FILTER
Three-phase power supply
Rated current (A)
(rating @ 50 °C/122 °F)
Approx. mass (kg/lb)
Rated leak current (mA)
Max. leak current (mA)
Power loss (W)
Sealing degree
Phase connection terminals Technical data.
T. H4/2
MAIN FILTER
Max. tightening torque (N·m)
Terminals Smin./Smax.
*
Without terminals. 6 10 mm holes with M10x20.4 screw and M10x1.8 bots
for power cable connection terminals.
MAIN FILTER 275A
42A-A
75A-A
380-480 V AC (50/60 Hz)
42
75
2.8/6.2
4.0/8.81
0.50
0.50
27
27
19
20
IP 20
IP 20
42A-A
75A-A
1.8
2.3
1/10
0.5/25
275A
275
13.8/30.4
< 80
600
42
IP 20
275A
24
*