  Description
1.2
1.
38
QC-PDS
HARDWARE
Ref.2003
· 30 ·

System Description

The QUERCUS servo drive by FAGOR is a compact and stackable
designed PDS. It is connected directly to a TN or TT three-phase mains
with line frequencies of between 50 (1-4 %) Hz and 60 (1+3.3 %) Hz and
line voltages between and 400 (1-10 %) V AC and 480 (1+10 %) V AC.
This system supplies the electric motors with a three-phase voltage of 400
(1- 4.5 %) V AC and a variable frequency with which it will govern its
speed.
Certain mandatory protection elements must be added between the mains
and the QC-PDS system. Others may be optional. These elements are:
Name
Main switch
Fuses
Differential breaker
Transformer or autotrans-
Contactor*
Mains filter
Chokes*
* only for
QC-RPS--
Depending on users needs, the QC-PDS system may consist of the follow-
ing modules:
Power supplies
·Non-regenerative· power supplies.
Stabilized regenerative power supplies
(rectifier/booster)
24 V DC auxiliary power supply
without a soft-start circuit or snubber circuit
+24 V DC auxiliary power supply
with a soft-start circuit and snubber circuit *
Drives
Single-drives
Dual-drives
Auxiliary modules
Mains filters
Coils
Bus protection module
Capacitor module
External braking resistors **
* only for
QC-RPS--
** must be installed on
INFORMATION. The QC-PDS system has been manufactured in
i
accordance with EN 60204-1 and is compliant with the European Directive
2014/35/EU on Low Voltage.
Symbol
Use
-S1
Mandatory
-Fi
Mandatory
-Q1
Mandatory
-T
Optional
-KM1
Mandatory
MAIN FILTER
Mandatory
CHOKE
Mandatory
regenerative power supplies.
regenerative power supplies.
non-regenerative power supplies.
QC-PS-
QC-PS-
QC-RPS--
QC-APS-15
QC-APS3-15
QC-DR--
QC-DR-+-FD2
MAIN FILTER-A-
CHOKE RPS--
QC-BPM-100
QC-CM-75
ER+TH-18/,
ER+TH-18/+FAN