Mains filters

It is recomended to insert a mains filter at each axis.
MANDATORY.
In order to comply with European Directive 2014/35/EU on Low Voltage (LVD) and
2014/30/EU on Electromagnetic Compatibility (EMC), it is mandatory to insert a
mains filter in the system.
Use the noise filter manufactured by · SCHAFFNER · at the brake power input for servomotors
with holding brakes.
Relationship between servo drive power and noise filter current:
SERVO DRIVE POWER NOISE FILTER CURRENT
0.75 kW
1.0 kW
1.5 kW
Note:
 single-phase servo drive should apply a two-phase filter. A three-phase servo drive
should apply a three-phase filter.
 Choose the right filter according the specifications of operating voltage, current, and
manufacturer.
 Recommended noise filter of 400 Vac servo drive:
SERVO DRIVE MODEL
BCSD-10DEG-EC
BCSD-15DEG-EC
BCSD-20DEG-EC
BCSD-30DEG-EC
BCSD-50DEG-EC
14|52 - BCSD EtherCAT
SERVO DRIVE POWER NOISE FILTER CURRENT
4 A
2.0 kW
4 A
3.0 kW
6 A
5.0 kW
· JIANLI · NOISE FILTER
DL-5EB
DL-10EB
DL-10EB
DL-15EB3
DL-25EB3
Beta series EtherCAT Servo Drives | Ref.2107
8 A
12 A
20 A
· SCHAFFNER · NOISE FILTER
FN3025HP-10-71
FN3025HP-10-71
FN3025HP-10-71
FN3025HP-20-71
FN3025HP-30-71