General information

Manager factory code 1-2-3-4-5-6.
A valid entry is followed by a double signal.
An invalid entry is followed by a long signal.
After 5 seconds without entry, current operation will be cancelled.

Penalty

After entry of 4 consecutive invalid codes the lock will be blocked for 5 minutes (penalty).
During penalty the LED flashes every 10 seconds.
During penalty any key pressed causes a long signal.
After penalty, entry of 2 more invalid codes restarts the 5 minutes blocking period.

Low battery signal

A series of signals indicates that the battery is weak and must be replaced.
Only use brand new 9V ALKALINE batteries.

Open the lock

• Enter the code (double signal).
• If time delay has not been set open the lock within 4 seconds.
• If time delay has been set wait for time delay counting: LED flashes every 2 seconds.
• A signal every 2 seconds indicates time delay counting is over and open window started.
• Enter the code (double signal) and open the lock within 4 seconds.
Change code (only change the code with safe door open).
• Press and hold 0 until double signal.
• Enter current user code (double signal).
• Enter new code (double signal) and repeat new code to confirm (double signal).
• Code has been changed: try new code with door open.
In case of any error (long signal) the old code remains valid.

Safety reference:

All codes are to be securely stored.
Do not use personal data (i.e. birthdays, phone numbers, etc.).
Change factory code before you start using the safe.

Install the user

• Press and hold 1 until double signal.
• Enter Manager code (double signal).
• Enter new user code (double signal) and repeat new code to confirm (double signal).
• User code has been installed: try new code with door open.
In case of any error (long signal) user code has not been installed.

Delete the user

• Press and hold 3 until double signal.
• Enter Manager code (double signal).
• User code has been deleted.
1
of
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PREMIER - 2 USERS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SmartLock PREMIER - 2 USERS

  • Page 1 P RE MI ER - 2 US ER S T ECH N I CAL MANUAL General information Manager factory code 1-2-3-4-5-6. A valid entry is followed by a double signal. An invalid entry is followed by a long signal. After 5 seconds without entry, current operation will be cancelled. Penalty After entry of 4 consecutive invalid codes the lock will be blocked for 5 minutes (penalty).
  • Page 2 Self diagnostic • Press and hold 5 until double signal. • Press each key consecutively 1-2-3-4-5-6-7-8-9-0 • Double signal: key properly working. • Long signal: damaged key. If no acoustig signal is emitted after pressing and holding 5, the lock is not properly connected to the keypad or the cable is damaged.

Table of Contents