Adjustment Of Swivel Angle For Mounting Variants G/H; Maintenance And Repair; Maintenance Of Rotary Actuator; Maintenance Ball Valve - bar agturn PKT Series Operating Manual

3/2-way automatic valve
Table of Contents

Advertisement

6.2.2 Adjustment of swivel angle for
mounting variants G/H
Setting the open valve position
1. If this is not already the case, allow the
actuator to swing into the open position.
Double-acting
compressed air to port 4, then bleed
air.
2. Loosen the lock nut (6b) of the right ad-
justing screw (5b).
3. Adjust the open valve position with the
adjusting screw (5b) and lock the adjust-
ing screw with the lock nut.
4. Close and open the valve and check
both end positions. If necessary, repeat
the points 1 to 4. If you also want to
adjust the other end position, continue
with point 5.
Setting the closed valve position
5. If this is not already the case, allow the
actuator to swing into the open position
and vent the actuator.
6. Loosen the lock nut (6a) of the left ad-
justing screw (5a) and make the adjust-
ment with the adjusting screw. Lock the
adjusting screw with the lock nut.
7. Close and open the valve and check
both end positions.
8. If the setting is correct, return the actu-
ator to the open position and vent the
actuator. If the setting needs to be cor-
rected again, repeat points 5 to 8.
32
actuators:
Supply
7. Maintenance and re-
pair
The automatic valve is a maintenance-free
device.
In terms of operational safety, however, it is
recommended to check them for function
and to switch at least every three months
but no later than after 50,000 switching cy-
cles; and in case of difficult operating condi-
tions even more often.
Do not use harsh detergents or abrasives to
clean the housings.
7.1
Maintenance of rotary
actuator
In principle, it is possible to repair the pneu-
matic rotary actuator by replacing the seal
and wear parts sets.
7.2

Maintenance ball valve

Repair and maintenance of the seal and
wear parts of the butterfly valve must not be
carried out because it is about high-pres-
sure glued ball valve.
NOTE
We recommend that you have the repair
carried out by the company bar GmbH.
We will be pleased to offer you a corre-
sponding servicing, maintenance or re-
pair. Please contact the company bar
GmbH for this.
PKT-GD/GS-IM-DE-B-EN-09-19 Rev.0

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for bar agturn PKT Series

Table of Contents