SPECIFICATIONS

Power
Type:
V+ Connection:
Common
Voltage:
DS71 Max Current:
DS72 Max Current:
Protection:
Logic Output Electrical Specifications
DS71 Sourcing Outputs
Connection:
Max. source current:
Output Voltage High:
Over-current protection:
ESD protection:
DS72 Sinking Outputs
Open Drain
Connection:
Max. applied voltage:
Max. current, momentary:
Max. current, sustained:
Max. off state leakage @ 30 V:
Over-current protection:
ESD protection:
DC
12 mm Connector, Pin 1
12 mm Connector, Pin 3
10 to 24 volts
40 milliamps + output loads
40 milliamps
Reverse polarity protected.
Transient Voltage Suppress @ 30 Volts
12 mm Connector, Pin 4
50mA, fuse limited
Supply Voltage less 1 volt
Self-resetting thermal fuse
Transient Voltage Suppressor @ 30 Volts
12 mm Connector, Pin 2
30 Volts, TVS limited
40 Amps
50mA, fuse limited
25uA
Self-resetting thermal fuse.
Transient Voltage Suppressor @ 30 Volts