Table of Contents

Advertisement

End Board

To battery +
To battery -
Info LED
Load status LED
Charge status LED
BMS IN
Button
Charge relay contacts
Load relay contacts
Extended data output
123electric
The Netherlands
E-mail: info@123electric.eu
www.123electric.eu
Mount hole for the 'plus'-pole of the cell.
Solder a wire on the solder pad and connect this wire to the minus (-)
side of the cell.
Indicator LED. Flashes when BMS data is received. Continuous ON
when the balance mode is active.
Flashes when load relay is active (every 5 seconds)
Flashes when charge relay is active (every 5 seconds)
Interconnection connector for the data link to the previous cell
board.
Button for Bluetooth configuration and password reset.
Relay for cutting off chargers, MPPT, solar chargers etc. In case of full
batteries.
Relay for cutting off consumers like inverters, etc. In case of empty
batteries.
Data output for external modules.