The App

First connection

Go to the App store for Apple devices and
search for "123SmartBMS". Install the
123SmartBMS App on your Apple device. For
Android devices go to the Play store and
search for "123SmartBMS". Install the App on
your Android device. Enable the Bluetooth
functionality of your device.
Start the App, You will see an overview of an
off-grid system. Tab settings in the right
bottom corner to open the settings section.

App Settings

Solar peak power: Set the maximum power of
your incoming energy source, for example
solar panels. If the system contains 10 solar
panels of 250 Watt each, the total power of
2.50 kW has to be configured.
Inverter peak power: Set the maximum power
of the consumers, for example an inverter.
When your inverter can supply 5 kilowatt,
5.00 kW has to be configured.
Battery capacity: The battery capacity can of
course be set to the total capacity of the
battery pack. We advise however to take only
80% of the rated capacity, to comply with cell
aging and temperature effects.
Example: If you use four 200 Ah cells  4 x
200 x 3.2 = 2560 Wh. In this case we advise to
use a value of 2560 x 0.8 = 2048 Wh  2.0
kWh.
Current sensor: Please set the current sensor
type you are using. The standard current
sensors supplied in the set are dual range
500A – 20A.
Critical mode:
Read extra info section B.
123electric
The Netherlands
E-mail: info@123electric.eu
www.123electric.eu
Tap on the discovered 123\SmartBMS device
to make a connection. The App will ask for a
password, this password is stored in the BMS
to prevent anybody with a Bluetooth device
can control your BMS. The default password is
"1234". After the connection has been made
it's time to configure the system.
To disconnect, tap again on the BMS ID with
the checkmark next to it.
Change PIN: It is recommended to change the
password of the BMS to prevent intruders can
sabotage the system. Tab the "change PIN"
line and follow the instructions.
Clear energy counters: Totals of incoming and
outgoing energy will be stored into the BMS. If
you like to set these total counters to zero, tab
the "Clear energy counters" line and follow
the instructions.
V min: If one of the cells gets below this
minimum cell voltage threshold the "Vl"
warning indicator on the battery details
screen is switched on. The "allow to
discharge" relay to control external devices
will be switched off.
V max: If one of the cells gets above this
maximum cell voltage threshold the "Vh"
warning indicator on the battery details
screen is switched on. The "allow to charge"
relay to control external devices will be
switched off.