Siemens SIMOTICS XP Series Operating Instructions Manual page 102

Low-voltage motors
Table of Contents

Advertisement

Operation
8.1 Safety instructions for operation
Explosion hazard if the bridging is removed from the insulated bearing
Removing the factory-fitted bridging of the insulated bearing leads to potential differences
between the rotor and the grounded motor. This can cause the generation of sparks, which
especially in an explosive atmosphere can ignite surrounding dust or combustible gases.
Explosions can occur. There is also a risk of an electric shock. Death, serious injury, or
material damage will result.
● Do not open the bridging of the bearing insulation during operation.
Overheating as a result of the anti-condensation heating
If the anti-condensation heating is operated while the machine is operational, this can
increase the temperatures inside the machine and cause material damage.
● Install an interlock circuit that switches off the anti-condensation heating once the main
machine is switched on.
● Only switch on the anti-condensation heating after the motor has been switched off.
Comply with the data stamped on the plate of the anti-condensation heating, if available.
Explosion hazard from hybrid mixtures
Hybrid mixtures are mixtures of flammable dusts with explosive gas/air atmospheres which
can together create a dangerous explosive atmosphere if they occur at the same time.
Changes can arise in the safety characteristics here, such as a change in the zonal
classification, increase in the explosion pressure, reduction in the minimum ignition energy
and a reduction in the maximum temperatures to be observed.
An explosion can result. This can result in death, serious injury or material damage.
● For this reason, the relative characteristics must be considered both for gas (zones 0, 1
and 2) and for dust (zones 20, 21 and 22) where hybrid mixtures arise. It is necessary for
a competent assessor to determine in the individual case whether the parameters
determining ignition are unfavorably affected in a particular hybrid mixture.
● Motors with dual plates for G ("Gas") and D ("Dust") may only be used where these two
occur after prior examination of the properties of the hybrid mixtures by the user.
Explosion hazard
These explosion-protected machines are not suitable for hybrid explosive environments.
This can result in death, serious injury or material damage.
Use in atmospheres where there is a risk of explosion caused by both gas and dust
simultaneously is absolutely prohibited.
100
WARNING
1MB..1/2/3/4 - shaft heights 63 ... 355
Operating Instructions, 06/2020, A5E44455710A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics xpSimotics xp 1mb series

Table of Contents