Troubleshooting - Ozone Solutions Waterzone Series Installation & Operation Manual

Ozone injection system
Hide thumbs Also See for Waterzone Series:
Table of Contents

Advertisement

Symptom
System does not run
Low dissolved ozone levels Water is contaminated
Low O2 flow
Low Air Pressure
Low O2 Pressure

Troubleshooting

Possible Cause
Alarm Condition - Message in alarm log
No Power
External stop contacts
Flow less than 5 gpm flow switch not ac-
tive
Water is too warm
Dissolved ozone reading is inaccurate
Oxygen flow is too low
Water flow is too high
Ozone Output is low
ORP high
Low outlet pressure
Low O2 Pressure
Flow restriction
Venturi pressure differential too low
Damaged O2 Regulation Valve
Air leak inside ozone generator
Pressure regulator requires adjustment
O2 or O3 Leak
Air Pressure Low
Repair
Resolve alarm condition
Check and repair incoming power
Ensure external contacts are open
Increase water flow
Check water quality, repair upstream deficiencies
Lower water temperature
Check dissolved ozone level against another
standard
Increase oxygen flow
Decrease water flow
Increase ozone generator output
Check ORP Set-points
Increase inlet flow/pressure or decrease outlet
flow
See section above
Open needle valve or dislodge restriction
Check water pressure being too high, check in-
jector & water pump operation
Replace regulation valve
Find and repair air leak
Adjust pressure regulator
Find and repair leak
See low air pressure