The OS3101 is designed to be used with a 24-VDC, negative
(protective) ground electrical system. Do not connect it to a
positive (protective) ground el ectrical system. Connecting the
OS3101 to a positive (protective)
the machine that is being controlled to fail to stop,
resulting in serious injury.
Do not connect any of the OS3101 lines
than 24 V+20%. Also, do not connect to an AC power
supply. Failure to do so may result in electric shock.
For the OS3101 to comply with IEC 61496-1 and UL 508, the DC
power supply unit should satisfy al l of the following conditions:
Should be within rated power voltage (24 VDC
Should comply with EMC Direct ives (industrial environment)
Double or enhanced insulation should be applied between the
primary and sec ondary circuits.
Automatic recovery of overcurr ent protection characteristics
Output holding time should be 20 ms or longer.
Should satisfy output characteristic requirements for class 2 circuit
or limited voltage current circuit defined by UL508.
Should comply with the EMC, laws, and regulations of the country
or region where the OS3101 is
power supply should comply with the EMC Low Voltage Directive.)
Double or enhanced insulation should be applied between the
OS3101 and hazardous voltage sources (such as 230 VAC) to
protect against electric shock.
The cable extension length should
length. Otherwise, the safety func tions may fail to work properly,
resulting in danger.
When the OS3101 is used in a category 3 safety system, use both
control outputs to build the safety system. Using only one control
output may result in serious injury due to a malfunction in the output
circuit.
The protective area should be co rrectly defined and the parameters
related to the protective area should
the protective functions of the OS3101.
When changing the response time of
should be recalculated and the OS
match the recalculated safety dist ance. Failure to do so may cause
the machine to fail to stop before an operator reaches the dangerous
area and may result in serious injury.
Do not allow the following types of light to shine directly on the
OS3101.
Incandescent light
Strobe light
Light from optical sensors using infrared light
If the Window is cracked, broken,
immediately. Failure to do so ma y lower the degree of protection.
Also, when replacing the Window, take the necessary steps to
prevent dust or other particl es from entering the OS3101.
If the Dust Ring is damaged, replace
may lower the degree of protection. Also, when replacing the Dust
Ring, take the necessary steps to pr
entering the OS3101.
To maintain the IP65 enclosure rating, make sure that there is no
foreign matter adhering to the seal s of the connectors, Window, or
Dust Ring, and that all screws are properly tightened.
Install the OS3101 securely.
When disposing of the OS3101, do so
and regulations for waste disposal
ground electrical system may cause
to a DC power supply higher
20%).
used. (Example: In the EU, the
be no greater than the specified
be correctly set in order to use
the OS3101, the safety distance
3101 should be re-installed to
or otherwise damaged, replace it
it immediately. Failure to do so
event dust or other particles from
in accordance with the laws
in the country where it is used.
Authorised Distributors:-
Intech Systems Chennai Pvt. Ltd
S-2, Thiru. Vi. Ka. Industrial Estate,
G u i n d y , C h e n n a i - 6 0 0 0 3 2
Ph: 4353 8888 Fax: 044 4353 7888
E - m a i l : i n f o @ i n t e c h c h e n n a i . c o m
Website: www.intechchennai.com
OS3101
14

Advertisement

Table of Contents
loading

Table of Contents