Specifications - Omron OS3101 Manual

Table of Contents

Advertisement

Specifications

Sensor type
Safety category
Detection capability
Monitoring area
Operating range
Maximum measurement error
Detection angle
Response time
Power supply voltage
Power consumption
Light source (wavelength)
Laser protection class
Control outputs (OSSD)
Auxiliary output
(non-safety output)
Alarm output
(non-safety output)
Output operation modes
EDM
Inputs
Start
Area selection
Connection type
Connection with a personal
computer *6
Indications
Protective circuits
Ambient temperature
Ambient humidity
Ambient operating light
intensity
Degree of protection
Casing material
Dimensions
Dielectric strength
Insulation resistance
Shock resistance
Vibration resistance
Weight
(Safety Laser Scanner only)
Power cable
Communications cable
Accessories
Applicable standards
*1. An additional tolerance for measurement error may be necessary due to background effects.
*2. For details on power supply specifications, refer to "Safety Precautions" on page 13.
*3. The maximum rated current for the OS3101 is 2.3 A (850 mA for the OS3101 plus the load for control output A, the load for control output B,
the auxiliary output load, and the alarm output load).
*4. The output voltage is the input voltage minus 2.0 VDC.
*5. Current consumption (the total of the two control outputs, the auxiliary output, and the alarm output) should not exceed 1.45 A.
*6. A USB-serial Conversion Cable is required for USB connection.
Type 3 Safety Laser Scanner
Category 3, 2, 1, or B safety applications
Opaque objects: 62-mm diameter (1.8% min. reflection factor)
Number of settable monitoring areas: Two sets of protective and warning areas
Protective area: 4-m radius max., warning area: 15-m radius max.
135 mm *1
180°
ON to OFF response time: 80 ms max. (2 scans) to 680 ms max. (17 scans max.)
OFF to ON response time: ON to OFF response time plus 400 ms
24 VDC±20% (ripple p-p 2.5 V max.) *2
20 W (with no output load) *3
Infrared laser diode (905 nm)
Class 1: IEC/EN 60825-1 (2001)
Class 1: JIS 6802 (2005)
Class I: CFR21 1040.10, 1040.11
PNP transistor output × 2, load current 625 mA max. *4 *5
PNP transistor output × 1, load current 100 mA max. *4 *5
PNP transistor output × 1, load current 100 mA max. *4 *5
Auto start, start interlock, start/restart interlock
ON: Short-circuit current of 0 V (input current: 50 mA), OFF: open
ON: Short-circuit current of 0 V (input current: 20 mA), OFF: open
ON: Connected to area selection COM (input current: 20 mA), OFF: open
Power cable: 14-pin special round connector
Communications cable: RS-232C 9-pin D-sub connector, straight cable
Communications: RS-232C, baud rate: 9600, 19200, 38400, 115200 bps
Applicable OS: Windows 2000, Windows XP Professional, Windows XP Home Edition
ON output indicator (green), OFF output indicator (red), interlock indicator (yellow),
alarm output indicator (orange)
Status/self-diagnosis display (2-digit, 7-segment indicator), intrusion indicator (red LED × 16)
Output load short-circuit protection, power supply reverse-connection protection
Operating: 0 to 50°C, storage: −25 to 70°C
Operating and storage: 95% max. (with no condensation)
Incandescent lamp: receiving-surface light intensity of 1,500 lx max.
(The angle between the laser scanning surface and the disturbance light should be ±8° min.)
IP65 (IEC 60529)
Aluminum die-cast
156.5 × 182 × 155.8 mm
350 VAC, 50/60 Hz for 1 min.
100 kΩ min. at 500 VDC
2
98 m/s
, 1,000 times each in X, Y, and Z directions (IEC 60068-2-29)
10 to 55 Hz, double amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions (IEC 60068-2-6)
3.7 kg
Maximum cable length: 30 m
Maximum cable length: 15 m
Instruction manual, CD-ROM (setting software), two surge killers
Certification institutes: TÜV Rheinland, UL
Applicable standards: IEC 61496-1/-3 type 3, EN 954-1 category 3, UL 508
OS3101
5

Advertisement

Table of Contents
loading

Table of Contents