Amana AVZC20 Series Service Instructions Manual page 80

Inverter heat pump condenser units with r-410a refrigerant blowers, coils, & accessories
Hide thumbs Also See for AVZC20 Series:
Table of Contents

Advertisement

7-SEGMENT DISPLAY
SCREEN 0 (Display FAULT CODE)
Setting
No.
1
SCREEN 1 (Display FAULT CODES)
Setting
No.
1
2
3
4
5
6
SCREEN 2 (MONITOR MODE)
Setting
No.
1
Compressor operation time
2
Operation code
3
Compressor Reduction Mode
4
% demand
5
act % demand
6
Requested ID CFM
7
Reported ID CFM
8
Outdoor FAN RPM
9
Ta (Outdoor Air Temperature)
10
Td (Discharge Temperature)
11
Tm (Outdoor Coil Temperature)
12
Tb (Defrost Sensor Temperature)
13
Tl (Liquid Temperature)
14
Pressure Sensor
80
Contents
Fault code (present)
Contents
Fault code (latest)
Fault code (2nd)
Fault code (3rd)
Fault code (4th)
Fault code (5th)
Fault code (6th)
Contents
Notes
Notes
Latest
2nd
3rd
4th
5th
6th
Notes
unit : hr (Multiply by 200,)
0: Stop
1: Cooling Start-up
2: Heating Start-up
3: Oil Return Operation
4: Heating Operation
5: Defrost Operation
6: Cooling Operation
0:OFF,1:ON
unit : %
(Cut off the decimal first place.)
unit : %
(Cut off the decimal first place.)
unit : CFM (Multiply by 10)
unit : CFM (Multiply by 10)
unit : RPM (Multiply by 10)
unit : F
unit : F
unit : F
unit : F
unit : F
unit : PSI