SERVICING
H
P
A
EAT
UMP
DVANCED
SUBMENU ITEM
CL Reset
Cool Airflow Trim Hi
Cool Airflow Trim Int
Cool Airflow Trim Low
Cool Airflow Profile
Cool ON Delay
Cool OFF Delay
Dehumidification Select
SUBMENU ITEM
Maximum Compressor RPS Range for Cooling (COOL
RPS RANGE)
Maximum Compressor RPS Selection for Cooling
(COOL RPS SELECT)
SUBMENU ITEM
HT Reset
Heat Airflow Trim Hi
Heat Airflow Trim Int
Heat Airflow Trim Low
Heat ON Delay
Heat OFF Delay
Maximum Defrost Interval
SUBMENU ITEM
Maximum Compressor RPS Range for Heating (HEAT
RPS RANGE)
Maximum Compressor RPS Selection for Heating (HEAT
RPS SELECT)
68
F
M
EATURE
ENU
COOL SETUP
USER MODIFIABLE OPTIONS
YES or NO
-15% to +15% in 3% increments
-15% to +15% in 3% increments
-15% to +15% in 3% increments
A, B, C, or D
5, 10, 20, 30 seconds
30, 60, 90, 120 seconds
ON or OFF
SET COOLING RUN VALUES (CL RUN VALUES)
USER MODIFIABLE OPTIONS
Five different compressor RPS ranges
will be provided.
10 compressor RPS values will be
provided within the range selected in
the COOL RPS RANGE menu
HEAT SETUP
USER MODIFIABLE OPTIONS
YES or NO
-15% to +15% in 3% increments
-15% to +15% in 3% increments
-15% to +15% in 3% increments
5, 10, 15 seconds
30, 50, 70, 90 seconds
30 mins., 1 hr., 1.5 hrs. & 2 hrs.
SET HEATING RUN VALUES (HT RUN VALUES)
USER MODIFIABLE OPTIONS
Five different compressor RPS ranges
will be provided.
10 compressor RPS values will be
provided within the range selected in
the HEAT RPS RANGE menu
COMMENTS
Selecting to default factory setting.
Selects the cooling airflow trim amount.
Selects the cooling airflow trim amount.
Selects the cooling airflow trim amount.
Selects the cooling airflow profile.
Selects the indoor blower ON delay.
Selects the indoor blower OFF delay.
Selecting OFF disables dehumidification; selecting ON
enables dehumidification.
COMMENTS
Select the appropriate range for the installed system
configuration.
Select the appropriate compressor RPS for the installed
system configuration.
COMMENTS
Selecting to default factory setting.
Selects the Heating airflow trim amount.
Selects the Heating airflow trim amount.
Selects the Heating airflow trim amount.
Selects the indoor blower ON delay.
Selects the indoor blower OFF delay.
Selects time defrost interval
COMMENTS
Select the appropriate range for the installed system
configuration.
Select the appropriate compressor RPS for the installed
system configuration.

Hide quick links: