I
opticalCON QUAD
®
G
FOCD-DW
4
HANDLING INSTRUCTION
FOCD-CF
1.9
After the cleaning procedure unlock the NEUTRIK
inspection tool (G).
2.
Wet cleaning using lint-free wipes
2.1
Press forward the twist prevention and untight the
connector bushing and remove carefully the insert of
the connector housing.
2.2
Inspect the LC connectors with a video probe tool.
2.3
Fold a lint free wipe into a square with one drop of
cleaning fluid. Be sure that a portion of the wipe
remains dry.
2.4
Wipe slightly the ferrule tip in the cleaning fluid
moistened portion of the wipe. Immediately repeat
this wiping action on the dry section of the wipe to
remove any residual alcohol.
2.5
Dispose the wipe. NEVER REUSE A WIPE.
2.6
Inspect the connector again with a video probe tool.
2.7
Repeat the process if necessary.
2.8
After the cleaning procedure slide the connector
insert back into the connector housing. Align the key
on the insert to the cutout of the metal housing.
2.9
Screw both connector parts togehter.