Fluke 417D User Manual page 27

Laser distance meters
Table of Contents

Advertisement

Maximum relative humidity
Safety
Laser
Max peak radiant output power
Wavelength
Pulse duration
Pulse repetition frequency
Beam divergence
EMC
International
KCC
USA (FCC)
[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C.
[2] Applies for 10 % to 500 % target reflectivity, high background illumination, −10 °C to +50 °C.
[3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.15 mm/m between 10 m to 30 m
and to 0.2 mm/m for distances above 30 m.
[4] Applies for 100 % target reflectivity, background illumination ~30,000 lux.
[5] After user calibration. Additional angle related deviation of ±0.01 ° per degree up to ±45 ° in each quadrant. Applies at room temperature. For the
whole operating temperature range the maximum deviation increases by ±0.1 °.
[6] After calibration. Do not use the compass for navigation.
417D
85 % at -7 °C to 50 °C (20 °F to 120 °F)
IEC 61010-1: Pollution Degree 2
IEC 60825-1: Class 2, 635 nm, <1 mW
0.95 mW
635 nm
>400 ps
320 MHz
0.16 mrad x 0.6 mrad
IEC 61326-1: Industrial Electromagnetic Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency
energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly
connected to a low-voltage power supply network that supplies buildings used for domestic
purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other
environments due to conducted and radiated disturbances.
Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the
seller or user should take notice of it. This equipment is intended for use in business environments
and not to be used in homes.
47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.