Figure 13. Pythagoras 2
3.
Push  for the first distance (diagonal) measurement.
4.
Point the laser at the second target (2).
Make sure that the Meter is perpendicular to the wall.
5.
Push  for the second distance.
6.
Point the laser at the third (3) target.
7.
Push  for the third distance measurement.
The Meter shows the result in the summary line. The
measured distance to the subsequent measurement shows
in the second line.
To find a partial distance with three measurements
(Pythagoras 3):
1.
Push  3x. The laser turns on and j shows on the display.
2.
Point at the top target (1). See Figure 14.
1
2
3
Figure 14. Pythagoras 3
3.
Push . The Meter stores this measurement value.
4.
Point the laser at the second diagonal target (2).
5.
Push  for the second distance measurement.
Make sure that the Meter is perpendicular to the wall.
6.
Push  to trigger the bottom target (3) measurement.
The result is the partial vertical distance between target 1
and target 2. The third measurement shows in the secondary
line.
As an option, use the tracking mode on one or more targets. To
use tracking mode:
1.
Push and hold  for 2 seconds to start tracking mode.
2.
Move the laser side to side and up and down on the ideal
horizontal target point.
3.
Push  to stop the tracking mode.