Poe Troubleshooting Suggestions; Additional Troubleshooting Suggestions - NETGEAR GS716TP Hardware Installation Manual

16-port gigabit (hi-power) poe+ ethernet smart managed pro switch with 2 sfp ports and cloud management
Table of Contents

Advertisement

16-Port Gigabit (Hi-Power) PoE+ Ethernet Smart Managed Pro Switch with 2 SFP Ports

PoE troubleshooting suggestions

Here are some tips for correcting PoE problems that might occur:
• Make sure that the PoE Max LED is off. If the PoE Max LED is solid yellow, disconnect
one or more PoE devices to prevent PoE oversubscription. Start by disconnecting
the device from the highest-numbered port.
• Make sure that the Ethernet cables are plugged in correctly. If the LED Mode Select
button is set to PoE mode, for each powered device (PD) that is connected to the
switch, the associated port LED on the switch lights solid green. If the port LED lights
solid yellow, a PoE fault occurred and PoE halted because of one of the conditions
that are listed in the following table.
Table 7. PoE fault conditions and possible solutions
PoE Fault Condition
A PoE-related short circuit occurred on the port.
The PoE power demand of the PD exceeded the maximum level that the switch
permits. The maximum level is 15.4W for a PoE connection or 30W for a PoE+
connection.
The PoE current on the port exceeded the classification limit of the PD.
The PoE voltage of the port is outside the range that the switch permits.

Additional troubleshooting suggestions

If the suggestions in the troubleshooting chart do not resolve the problem, see the
following troubleshooting suggestions:
• Network adapter cards. Make sure that the network adapters that are installed in
the computers are in working condition and the software driver was installed.
• Configuration. If problems occur after you alter the network configuration, restore
the original connections and determine the problem by implementing the new
changes, one step at a time. Make sure that cable distances, repeater limits, and
other physical aspects of the installation do not exceed the Ethernet limitations.
• Switch integrity. If necessary, verify the integrity of the switch by resetting it. To
reset the switch, disconnect the power from the switch and then reconnect the power.
Troubleshooting
34
Possible Solution
The problem is most likely
with the attached PD. Check
the condition of the PD or
restart the PD by
disconnecting and
reconnecting the PD.
Restart the switch to see if the
condition resolves itself.
Hardware Installation Guide