12. Run an alkaline wash cycle (see page 29).
13. Disconnect and drain the wash tank then close the wash tank drain valve.
14. Perform a permeability test (see page 21).
a. Compare the results to the results of the test run when the system was new or at the completion of
preparation for storage at the end of the previous season. If the results are not acceptable contact
LEADER EVAPORATOR or your local Distributor / Dealer for assistance.
b. Record the results, if acceptable, and use these results as the reference for test for the season.

TROUBLESHOOTING CHART

The following conditions may occur during operations.
CONDITION
Feed pump does not start when
START button is pressed
Feed pump starts but system does
not continue running
Low rate found during permeability
test
Sugar in the permeate
Leader Evaporator Springtech MicRO Reverse Osmosis System Manual
CAUSE
No power
Low pressure
No liquid coming from storage
Suspected bacteria buildup
Suspected Mineral Buildup
Leak at seal
Membrane deterioration
ACTION
Verify power is "ON" at the source.
Ensure pressure switch is in the Start
(Down) position
Inspect incoming plumbing for leaks
Check and clean Y-strainer
System needs to be bled
Check the positions of all valves and
hoses
Rewash system with R/O alkali soap
Acid wash system
Replace seal on membrane
Replace membrane