Wash Cycle Settings / Positions – also available on the Quick Start Guide
1. Position V2 valve and the hoses as follows:
2. Add the chemical to be used into the wash tank for the type of wash to be performed. Ensure the wash tank
has been filled first.
3. Place the Pressure Switch (located in the center of the front panel) in the START (Down) position.
4. Start the feed pump (bottom pump)
5. Run the feed pump until most of the air has been purged from the flow meters on the front of the machine.
6. Start the pressure pump (upper pump).
7. Place the Pressure Switch in the RUN (Up) position.
8. Run the wash cycle as specified above; Acid Soap Wash, Acid Soak.
9. Stop the system.
10. Do a permeability test (see page Permeability Test
11. If the test is good, continue to rinse with any additional permeate.
Leader Evaporator Springtech MicRO Reverse Osmosis System Manual
V2 – Open completely.
Place the output end of the concentrate hose into the
wash tank.
Place the output end of the permeate hose into the wash
tank.
Connect the input side of the feed pump to the wash tank.