System Fluid Input Connection

The system input is to be setup so the connection can be easily disconnected and reconnected as necessary. The
following is the recommended connection detail.

Vessel and Pump Drains

Leader Evaporator Springtech MicRO Reverse Osmosis System Manual
1. Remove the PVC threaded plug from the end of the pump.
2. Obtain a 1" "F" style quick connector.
3. Teflon tape the threaded end.
4. Thread the "F" connector into the feed pump and tighten the connector.
5. Obtain a length of 1" braided hose that will connect to the strainer output.
6. Slide a 1" stainless steel band clamp over one end of the hose.
7. Slide the hose onto a 1" C style quick coupler and tighten the clamp over
the coupler.
8. Pull the metal latches on the quick coupler out to the sides (perpendicular
to the body of the quick coupler) then slide the open end of the coupler
over the F style coupler on valve V6.
9. Raise the metal latches on the quick coupler back to the side of the C quick
coupler while pressing the couplers together.
The Membrane Vessel drains are located under the
membrane vessels. To drain the vessels remove the
heavy duty clamps and the caps. NOTE: Use caution
when removing clamps and caps as the membrane may
slide down out of the vessel as the cap is removed.
 The feed pump drain is a 7/16" stainless steel plug
located on the front of the pump housing.
 Pressure pump drain is a 7/16" stainless steel plug
located on the front of the pump housing.
YEAR: 2017
Page: 13