Installation
The oven must be installed according to the
instructions supplied.
Technical Data
Dimensions of recess
Height
Width
Depth
Dimensions of the oven cavity
Height
Width
Depth
Oven capacity
Electrical Connection
The oven is designed to be connected to 230-240V (50Hz)
electricity supply.
The oven has an easily accessible terminal block which
is marked as follows:
Letter L
-
Live terminal
Letter N
-
Neutral terminal
or E
-
Earth terminal
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical
supply must comply to the specifications given below.
For Uk use only
Connection
Min. size
via
Cable/flex
• Cooker
2.5 mm
Control
Circuit
For Europe use only
Min. size Cable/flex
2.5 mm
2
22
580 mm.
560 mm.
550 mm.
335 mm.
395 mm.
400 mm.
53 litres
Cable / flex Fuse
type
PVC/PVC
20 A
2
twin and
earth
Cable / flex type
Fuse
H07 RN-F, H05 RN-F, 15 A
H05 RR-F, H05 VV-F,
H05 V2V2-F (T90),
H05 BB-F
This oven must be installed by qualified
personnel to the relevant British Standards.
Heating elements rating
Oven element
Top element
Bottom element
Convection element
Grill element
Double Grill element
Pizza Oven Function
Convection Fan
Oven Light
Cooling Fan
Total Rating
Supply voltage (50 Hz)
It is necessary that you install a double pole switch
between the oven and the electricity supply (mains), with
a minimum gap of 3mm between the switch contacts
and of a type suitable for the required load in compliance
with the current rules.
The switch must not break the yellow and green earth
cable at any point.
Important
After installation and connecting, the cable must be
placed so that it cannot at any point reach a temperatu-
re of more than 60°C above the ambient temperature.
Before the oven is connected, check that the main fuse
and the domestic installation can support the load; and
that the power supply is properly earthed.
The manufacturer disclaims any responsibility should
these safety measures not be carried out.
1,880 W
835 W
1,045 W
2,090 W
1,795 W
2,665 W
3,135 W
30 W
15 W
25 W
3,200 W
230-240 V