Clock Modes - Synchronization - RME Audio HDSPe AIO Pro User Manual

Pci express digital i/o card
Table of Contents

Advertisement

8.5 Clock Modes - Synchronisation
In the digital world, all devices must be either Master (clock source) or Slave (clock receiver).
Whenever several devices are linked within a system, there must always be a single master
clock.
!
A digital system can only have one master! If the card's clock mode is set to 'Internal', all
other devices must be set to 'Slave'.
The HDSPe AIO Pro's utilizes a very user-friendly, intelligent clock control, called AutoSync. In
AutoSync mode, the system constantly scans the digital input for a valid signal. If any valid signal
is found, the card switches from the internal clock (Clock Mode – Current Internal) to a clock
extracted from the input signal (Clock Mode – Current ADAT, AES, SPDIF or Sync In). The dif-
ference to a usual slave mode is that whenever the clock reference fails, the system will auto-
matically use its internal clock and operate in clock mode Master.
AutoSync guarantees that normal record and record-while-play will always work correctly. In
certain cases however AutoSync may cause feedback in the digital carrier, so synchronization
breaks down. To remedy this, switch the HDSP's clock mode over to 'Internal'.
RME's exclusive SyncCheck technology enables an easy to use check and display of the cur-
rent clock status. The status box labelled Input Status indicates whether no signal ('No Lock'), a
valid signal ('Lock') or a valid and synchronous signal ('Sync') is present at each of the digital
clock source inputs. In the field Clock Mode the clock reference is shown. See chapter 30.1.
Via Clock Source a preferred input can be defined. As long as the card sees a valid signal there,
this input will be designated as the sync source, otherwise the other inputs will be scanned in
turn. If none of the inputs are receiving a valid signal, the HDSPe automatically switches into
clock mode Master.
Under WDM the unit will (has to) set the
sample rate. Therefore the error shown
to the right can occur. A stable signal
with a sample rate of 32 kHz is detected
at the Word Clock input (Sync), but Win-
dows audio had been set to 44100 Hz
before. The red colour of the text label
signals the error condition, and prompts
the user to set 32000 Hz manually as
sample rate.
Under ASIO the audio software sets the sample rate, so that such an error will usually not hap-
pen – but it can too. In slave mode the external sample rate has priority. Feeding 44.1 kHz will
prevent the ASIO software to set 48 kHz – obviously, as the only way to do so would be to enter
a different clock mode (Master/Internal).
In practice, SyncCheck provides the user with an easy way of checking whether all digital devic-
es connected to the system are properly configured. With SyncCheck, finally anyone can master
this common source of error, previously one of the most complex issues in the digital studio
world.
18
User's Guide HDSPe AIO Pro © RME

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents