"ENABLE" INPUT

The enable input allows the whole power pack to be enabled and
disabled remotely.
Note: If the enable input is not connected the
power pack will not work.
Permanently enabled If you require the DP10000 to be
permanently enabled link the ENABLE input to the +10 V
terminal.
Remotely enabled and disabled To use the 'enable' facility, connect
the 0−10 V switching output from the 'enabling' controller (probably
a switch/touch panel) to the enable input of the DP10000. Connect
the common/0 V output from the 'enabling' controller to the 0V
terminal.
A switch may be used if there is no controller available: take the +
10V output from the DP10000 through the switch and back to the
ENABLE input
+15 V Out . A +15 V DC output is provided to supply lighting
controllers such as the Fade 4. A maximum of 100 mA may be
taken from this output.
Cable for analogue inputs. For short cable runs (less than 5
metres, in areas away from mains power cables, use 6-core cable
of the type used in burglar alarms or telephone systems, or similar.