cables too close to sensitive audio circuits. Improved performance
can be achieved as follows:
• Each output channel should have its own separate neutral wire of
the same length and thickness as the live wire
• Each live output wire should be twisted together with its
corresponding Neutral.
• The neutrals from all four channels should be commoned only at
the terminal block inside the DP10000.
ANALOGUE INPUTS
Connect the outputs from any light controller with 0 to +10 V
analogue outputs to the 6-way terminal block labelled "4 3 2 1
ENABLE 10V 0V 15V"
The DP10000 can only be used with 0 to +10 V inputs.
The DP10000 cannot be used with controllers which produce 0 to
−10 V or 0 to +6 V outputs.
C
onnect the common to the 0 V terminal and the four signal wires
to the terminals labelled 1, 2, 3 and 4.
Page 6