NJD Electronics NJ250 DP10000 Manual page 3

4x10 a analogue dimming pack
Table of Contents

Advertisement

Connect the incoming mains supply (230 V) to the large terminal
block using 6 mm
cable:
2
• Connect the incoming LIVE supply to the large terminal block
labelled "LIVE".
• Connect the incoming NEUTRAL supply to the large terminal block
labelled "NEUTRAL"
• Connect the incoming EARTH to the brass terminal block labelled
with the EARTH symbol. The DP10000 must be earthed.
If connected to a supply of lower capacity than 40 A, the
outputs must be reduced as follows:
• For a 13 A supply , the maximum total load is 2990 W which can
be made up of: either: 745 W watts on each of the four channels
or: different loads on each channel so that the total does not exceed
2990 W (but not more than 2300 W on any one channel) or:
2300 W load may be connected to all four channels provided that
the unit is operated so that all four channels are not switched on
together at full power.
• For a 16 A supply , the maximum total load is 3680 W which can
be made up of: either: 920 W watts on each of the four channels
or: different loads on each channel so that the total does not exceed
3680 W (but not more than 2300 W on any one channel) or: