I
C
NTEGRATED
IRCUITS
Absolute Maximum Ratings @ 25ºC
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation
1
Total Power Dissipation
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
1
Derate linearly 3.33 mW / ºC
Electrical Characteristics @ 25ºC
Parameter
Output Characteristics
Load Current
1
Continuous
Peak
2
On-Resistance
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Input Characteristics
Input Control Current to Activate
Input Control Current to Deactivate
Input Voltage Drop
Reverse Input Current
Common Characteristics
Capacitance, Input to Output
1
Load current derates linearly from 100mA @ 25ºC to 80mA @ 80ºC.
2
Measurement taken within 1 second of on-time.
3
For applications requiring high temperature operation (greater than 60ºC) a minimum LED drive current of 3mA is recommended.
2
D
IVISION
Ratings
Units
60
V
P
5
V
50
mA
1
A
70
mW
400
mW
1500
V
rms
-40 to +85
ºC
-40 to +125
ºC
Conditions
I
=2mA
F
t=10ms
I
=100mA
L
V
=60V
L
P
I
=5mA, V
=10V
F
L
I
=0mA, V
=50V, f=1MHz
F
L
3
I
=100mA
L
-
I
=5mA
F
V
=5V
R
V
=0V, f=1MHz
IO
www.ixysic.com
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to the
device. Functional operation of the device at conditions beyond
those indicated in the operational sections of this data sheet is
not implied.
Typical values are characteristic of the device at +25°C, and
are the result of engineering evaluations. They are provided for
information purposes only, and are not part of the manufacturing
testing requirements.
Symbol
Min
I
-
L
I
-
LPK
R
-
ON
I
-
LEAK
t
-
on
t
-
off
C
-
OUT
I
-
F
I
0.3
F
V
0.9
F
I
-
R
C
-
IO
CPC1017N
Typ
Max
-
100
mA
-
±350
-
16
-
1
-
10
-
10
5
-
0.4
1
-
-
1.2
1.5
-
10
1
-
Units
/ mA
rms
DC
mA
P
A
ms
ms
pF
mA
mA
V
A
pF
R10