Technical Technical Data - Kemppi Minarc 150 Service Manual

Hide thumbs Also See for Minarc 150:
Table of Contents

Advertisement

Technical data
Supply voltage, 1~ 50/60 Hz
Loadability
35% ED (MMA)
100% ED (MMA)
35% ED (TIG)
100% ED (TIG)
Supply cable / fuses
Welding current range (MMA)
Suitable stick sizes
Welding power adj.
OCV
Idling power
Efficiency
Power factor
Temperature class
Operation temperature range
Stock temperature range
Casing class
Norms
Dimensions
Length
Width
Height
Weight
Minarc 150
230 V ± 15%
140 A (7,5 kVA)
100 A (5,1 kVA)
150 A (5,0 kVA)
110 A (3,3 kVA)
2,5 mm² S / 3,3 m 16 A
10 A / 20,5 V...140 A / 25,6 V 10 A / 20,5 V...140 A / 25,6 V 10 A / 20,5 V...140 A / 25,6 V
ø 1,5...3,25 mm
Stepless
~ + 85 V
< 10W
0,8
0,60 (140 A / 25.5 V)
B (130°C) / H (180°C)
-20...+40°C
-40...+60°C
IP 23C
IEC 60974-1, -10
EN 50199
320 mm
123 mm
265 mm
4,0 (4,6) kg
Minarc 150
VRD
230 V ± 15%
140 A (7,5 kVA)
100 A (5,1 kVA)
150 A (5,0 kVA)
110 A (3,3 kVA)
2,5 mm² S / 3,3 m 16 A
ø 1,5...3,25 mm
Stepless
~ + 30 V
< 10W
0,8
0,60 (140 A / 25.5 V)
B (130°C) / H (180°C)
-20...+40°C
-40...+60°C
IP 23C
IEC 60974-1, -10
EN 50199
320 mm
123 mm
265 mm
4,0 (4,6) kg
Minarc 151
110 V ± 15%
140 A (7,5 kVA)
100 A (5,1 kVA)
150 A (5,0 kVA)
110 A (3,3 kVA)
6 mm² S / 2,0 m 32 A
ø 1,5...3,25 mm
Stepless
~ + 85 V
< 10W
0,8
0,60 (140 A / 25.5 V)
B (130°C) / H (180°C)
-20...+40°C
-40...+60°C
IP 23C
IEC 60974-1
EN 50199
320 mm
123 mm
265 mm
4,4 (5,2) kg
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Minarc 150 vrdMinarc 151

Table of Contents