Special tools (Unit: mm)
Mark
Holding bar
A
B
φ9
114
Inspection and cleaning procedure
Removal procedure
Tool name and shape
Inspection: Automatic cooling fan coupling
• Make an inspection of the following points. Replace the automat-
ic cooling fan coupling if defective.
Check that:
• the hydraulic oil sealed inside the coupling is not leaking;
• the coupling does not make any abnormal noise or rotate un-
• the automatic cooling fan coupling does not move too much
Cleaning: Automatic cooling fan coupling
• When removing foreign matter from the bimetal, be careful not to
press too hard against the bimetal.
CAUTION
• Be careful not to deform the bimetal.
Removal: Fan pulley
• Put
by using nuts.
• While holding
Part No.
MH062970
evenly due to defects in the inside bearing when rotated man-
ually; and
when pushed and pulled in the axial directions when the en-
gine is cold.
in position on the studs of the fan pulley and fix the tool
, loosen the fan pulley mounting nut.
Application
Holding of fan pulley
14
14-23