Myson RIO Series Installation Operating And Maintenance Istructions

Myson RIO Series Installation Operating And Maintenance Istructions

Advertisement

MYSON
Purmo Group (UK) Ltd
Eastern Avenue, Team Valley
Gateshead, Tyne & Wear
NE11 0PG, UK
T: 0845 402 3434
F: 0191 491 7568
sales@purmogroup.com
www.myson.co.uk
RIO range
Installation, operating, and instruction manual
Please leave this manual with the end user
Class I - 230V - 50 Hz
Register your warranty
online at www.myson.co.uk

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RIO Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Myson RIO Series

  • Page 1 Gateshead, Tyne & Wear Installation, operating, and instruction manual NE11 0PG, UK T: 0845 402 3434 Please leave this manual with the end user F: 0191 491 7568 sales@purmogroup.com www.myson.co.uk Class I - 230V - 50 Hz Register your warranty online at www.myson.co.uk...
  • Page 2: Table Of Contents

    Contents 1.0 Warnings & Safety Information Safety information Children of less than Warnings & Safety Information 3 years should be kept General Information This appliance can be away from the unit unless Installation Maintenance, Repair & Disposal used by children aged continuously supervised.
  • Page 3: Warnings & Safety Information

    1.0 Warnings & Safety Information 1.0 Warnings & Safety Information (cont...) (cont...) CAUTION Any repairs or maintenance within the warranty The radiator is filled with an exact amount shall therefore only be carried out by the period should be carried out only by approved of environmental friendly vegetable oil.
  • Page 4: Installation

    3.0 Installation 3.0 Installation (cont...) POSITIONING RIO Double Panel (refer to figure 2) The radiator must be positioned horizontally, Height (mm) the right way up on the wall in order for it to function correctly. Never switch the radiator on in any other position as this will damage Min.
  • Page 5: Waste Disposal According To The Weee Directive (2002/96/Ec)

    5.0 Waste Disposal According to The WEEE Directive (2012/19/EU) 7.2 Behaviour Indicator Waste disposal according to the negative effects on the environment and As you increase the temperature setting, the WEEE Directive (2012/19/EU). health to which the product can contribute if behaviour indicator “bar”, in section 8 of the LCD The symbol on the product label it is disposed of as ordinary domestic waste.
  • Page 6: Standby Mode

    8.4 Standby Mode 8.5 Automatic Mode 8.7 Defining a User Programme NOTE: Once saved, the user defined programmes In this mode the radiator is This mode is only to be used when switched off. connected to a TOUCH4 programmer, or are not lost in the event of a power cut.
  • Page 7 8.7 Defining a User Programme 8.7 Defining a User Programme (cont...) (cont...) Comfort to Reduced. The symbol will start to blink instead of the symbol, signifying the start of this Reduced period. If more than two Comfort periods are required, repeat the previous steps. Use the “+”...
  • Page 8: Timed Override Mode

    8.8 Timed Override Mode 10.0 Window Open Function Timer mode allows Then, adjust the duration in hours “H” if The radiator is equipped with a the function is active. To return to the previous temperature and heating period to be below 24H, then in day “D”...
  • Page 9 11.0 Parameter’s Menu 11.0 Parameter’s Menu (cont...) (cont...) N° N° Default value & other possibilities Default value & other possibilities XX.X : Calibration of the Internal Probe Wind : Open Window Detection (the text “U – ind” is displayed) The calibration must be done after 1 day working with the same setting temperature in accordance with the following description: Press the “OK”...
  • Page 10: Technical Characteristics

    11.0 Parameter’s Menu 12.0 Technical Characteristics (cont...) N° Default value & other possibilities Environmental: Operating temperature -10°C - +50°C CLr : Factory Setting Shipping and storage temperature -30°C to +70°C Press and hold the “OK” key for 6 seconds to reset Set point temperatures and all user Electrical protection Class 1 - IP44 parameters in this menu to factory default settings.
  • Page 11: Radiator Connect To The Touch4 Programmer

    13.0 Radiator Connected to the TOUCH4 Programmer 13.0 Radiator Connected to the TOUCH4 Programmer (cont...) Wire Colours PILOT WIRE FROM BR = Brown PROGRAMMER A suitable means of local isolation of the BK = Black (switched live) Touch 4 radiator from both the electrical supply and the BL = Blue Wire Colours pilot wire signal must be provided.
  • Page 12: Troubleshooting & Solution

    14.0 Troubleshooting & Solution 15.0 Preset Programmes Q: My Thermostat shows an Error message “Err” blink on the display. The text “Err” flashes. Error detected on the internal sensor. Contact your installer or seller. Q: My Thermostat seems to work correctly but the heating doesn’t work correctly. Is there a window open next to the radiator that is not heating? Check the settings in Parameter 05 (on page 17).
  • Page 13: Eco Directive Characteristics

    With working time limitation In standby mode eI SB <0.001 With black bulb sensor Contact details MYSON Purmo Group (UK) Ltd., Eastern Avenue, Team Valley, Gateshead, Tyne & Wear NE11 0PG, UK T: 0845 402 3434, F: 0191 491 7568, sales@purmogroup.com, www.myson.co.uk...