General information General information INFORMATION This documentation describes the differences between DRN71 – DRN132LS motors ® with MOVILINK DDI interface and standard motors. This document is an addendum to the detailed operating instructions "DR..71 – 315, DRN63 – 315, DR2..63 – 80 AC Motors". ® Addendum to the Operating Instructions – AC Motors with MOVILINK DDI Interface...
Motor structure Basic structure DRN71 – DRN132LS motors Motor structure INFORMATION The following figures are block diagrams. They are to facilitate the assignment of components to the spare parts list. Motor size and design may cause deviations. Basic structure DRN71 – DRN132LS motors [707] [705] [103] [100]...
Motor structure DRN.. motor nameplate DRN.. motor nameplate The following figure shows an example of a nameplate of a gearmotor with ® MOVILINK DDI interface: 30534533643 Type designation ® MOVILINK DDI interface identification Motor type designation The following table shows the structure of a motor type designation: DRN132M4/BE11/HR/FI/TF Product family Code for product line identification...
Motor structure Type code MOVILINK® DDI interface identification Type code MOVILINK® interface identificatio ® Type code MOVILINK DDI interface identification The following diagram shows the structure of the MOVILINK® DDI interface: DI0C00 ® DI = MOVILINK ® 0 = No brake control via MOVILINK DDI •...
Do not change the connection type. Terminal box INFORMATION It is not permitted to change the position of the terminal box. If the terminal box must be rotated, contact SEW-EURODRIVE. ® Addendum to the Operating Instructions – AC Motors with MOVILINK DDI Interface...
Electrical installation Terminal box connections Electrical installation INFORMATION Do not change the connection type. Terminal box connections The terminal board for the power connection is separated from the part of the terminal ® box, where MOVILINK DDI is connected by a plastic partition [1]. 30494955659 1.
Page 10
Electrical installation Terminal box connections The yellow core (YE) /A [3] must not be connected. Insulate the yellow core and ar- range it as shown in the following figures. 30494960523 2. Attach plastic cover depicted. For mechanical protection, fasten the yellow core to the plastic cover [4] as depic- ted in the figure.
Page 11
Electrical installation Terminal box connections 30494965387 ® Addendum to the Operating Instructions – AC Motors with MOVILINK DDI Interface...
Electrical installation Connection with plug connectors Connection with plug connectors The cable entry of the power and signal cables is installed using plug connectors. Comply with the permitted bending radii of the cables. 4.2.1 Representation of connections The wiring diagrams of the plug connectors depict the contact end of the connections. ®...
Electrical installation Connection with plug connectors ® 4.2.3 Motor connection for motors with brake with MOVILINK DDI interface The following table shows information about this connection: Function ® Motor connection for units with digital interface (MOVILINK DDI) Connection type M23, male, male thread, TE Connectivity - Intercontec Products, series 723, SEW in- sert, SpeedTec equipment, coding ring: without, protected against contact Connection diagram Assignment...
® Motor cables for DRN.. motors with MOVILINK DDI interface Connection cable, fixed installation ® Motor cables for DRN.. motors with MOVILINK DDI interface The following tables list the cables available for this connection. Connection cable, fixed installation Connection cable Conformity/ Cable type Length/installa-...
® Motor cables for DRN.. motors with MOVILINK DDI interface Connection cable, cable carrier installation Connection cable, cable carrier installation Connection cable Conformity/ Cable type Length/installa- Cable cross part number tion type section/operat- ing voltage ® CE/cURus: LEONI LEHC Variable 4 × 1.5 mm + 28123743...
® Motor cables for DRN.. motors with MOVILINK DDI interface Motor cable connections for DRN.. motors without brake with MOVILINK® DDI interface Motor cable connection s for DRN.. motors without brake with MOVILINK® interface ® Motor cable connections for DRN.. motors without brake with MOVILINK DDI interface Connecting the cable with connectors on the motor end.
Page 17
® Motor cables for DRN.. motors with MOVILINK DDI interface Motor cable connections for DRN.. motors with BE brake with MOVILINK® DDI interface Motor cable connection s for DRN.. motors with BE brake with MOVILINK® interface ® Motor cable connection for DRN.. motors with BE brake with MOVILINK DDI interface Connecting the cable with connectors on the motor end.
Technical data of encoders Technical data of encoders Single-turn resolution Multi-turn resolution Interface con- System data encoder option (Position resolution per (Max. counter for com- nection motor revolution) plete motor revolutions) /EI8Z ® MOVILINK DDI, 12 bits 4096 inc. – – coaxial Single-turn absolute encoder ®...
® Dimension sheets of DRN.. with terminal box for MOVILINK ® Dimension sheets of DRN.. with terminal box for MOVILINK 71MS 80MK 80MS 90S(R) LB (B5/B14) LB (B3) LBS (B5/B14) LBS (B3) ® Addendum to the Operating Instructions – AC Motors with MOVILINK DDI Interface...
Page 25
® Dimension sheets of DRN.. with terminal box for MOVILINK 100LS 100LM 100L 112M(B) 132S LB (B5/B14) LB (B3) LBS (B5/B14) LBS (B3) ® Addendum to the Operating Instructions – AC Motors with MOVILINK DDI Interface...
Page 28
SEW-EURODRIVE—Driving the world SEW-EURODRIVE GmbH & Co KG Ernst-Blickle-Str. 42 76646 BRUCHSAL GERMANY Tel. +49 7251 75-0 Fax +49 7251 75-1970 sew@sew-eurodrive.com www.sew-eurodrive.com...
Need help?
Do you have a question about the DRN Series and is the answer not in the manual?
Questions and answers