Step
Instruction: Some wiring terminal of this
product is with lock catch and other devices.
The pulling method is as below:
1.Remove the soft sheath for some terminals
terminals.
2.Pull out the holder for some terminals at
terminal), hold the connector and then pull the
terminal.

8. Remove evaporator assy

a
At the back of the unit, remove the
b
then remove the connection pipe clamp.
c
First remove the left side of the evaporator
from the groove of bottom case and then
remove the right side from the clasp on
the bottom case.
d
Adjust the position of connection pipe
on evaporator slightly and then lift the
evaporator upwards to remove it.
98
Procedure
circlip
soft sheath
Connection pipe clamp
Groove
Evaporator assy
Screws
Evaporator assy
Screw
Bottom case
Connection pipe
Installation and Maintenance
Service Manual
holder
connector
Clasp