Table 4-19
Parameter
eject_area
volser_range
type
pnActualCount
aci_ei_info
4-52
DAS ACI Functions
See Table 4-19 for a description of the parameters for the
aci_eject2_complete function call.
Parameters for the aci_eject2_complete Function Call
logical area defined in AML, where the cartridges
should be ejected
• a single volser
• multiple volsers separated by commas
• a range of volsers separated by a hyphen
• set to empty ("" or '\0') if it is not to be changed
media type of the named volser range
Refer to Media Types on page 2-7
returned number of ejected volsers
returned information to each ejected volser
volser
type
errcode
If the eject area is full the system stops the eject procedure.
Depending on the DAS_EJECTAREAFULL environment
variable on the AMU, the command will be canceled, or the
system starts with the next eject after the operator has
removed cartridges from the eject area.
The attribute of the coordinate will be set to empty in the
AMU database. The volser will be set to 0000000000000000,
but the type will remain unchanged. The compartment is
ready for the other volsers.
For additional information, refer to aci_insert on page 4-75,
and aci_eject2 on page 4-42.
Description
volser of the ejected volume
media type of the named volser
Refer to Media Types on page 2-7
Error code derrno
601626-B