EMKO EGG HATCHER User Manual

EMKO EGG HATCHER User Manual

Hatching control device

Advertisement

Quick Links

EMKO ELEKTRONİK A.Ş.
Demirtaş Org. San. Blog.
Karanfil Sk. No:6 TR
16369 Bursa / TURKEY
Telefon:0224 261 1990
Faks:
0224 261 1912
Web Sitesi:
www.emkoelektronik.com.tr
email:
exposales@emkoelektronik.com.tr
EGG HATCHER
HATCHING CONTROL DEVICE
USER MANUAL
User Manual ENG EGG HATCHER 02 V01 04/16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EGG HATCHER and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EMKO EGG HATCHER

  • Page 1 HATCHING CONTROL DEVICE USER MANUAL EMKO ELEKTRONİK A.Ş. Demirtaş Org. San. Blog. Karanfil Sk. No:6 TR 16369 Bursa / TURKEY Telefon:0224 261 1990 Faks: 0224 261 1912 Web Sitesi: www.emkoelektronik.com.tr email: exposales@emkoelektronik.com.tr User Manual ENG EGG HATCHER 02 V01 04/16...
  • Page 2: Table Of Contents

    Tray Rotation Parameters 6.1.9 Hatching Parameters Device Settings ........................28 6.2.1 Date & Time Settings 6.2.2 Update Software 6.2.3 Default Settings 6.2.4 Change Password LOGS ..............................8 ALARMS............................32 9 LANGUAGE SELECTION ......................33 ALARM TYPES ......................... ENG EGG HATCHER 02 V01 04/16...
  • Page 3: Introduction

    SPECIFICATIONS ......................35 OTHER INFORMATIONS ....................36 1. INTRODUCTION 1.1. General Specifications ENG EGG HATCHER 02 V01 04/16...
  • Page 4: Warranty

    Emko Elektronik, warns the user that the device has complex structure and may not be completely free of errors. It's the responsibility of the user to make provision by installing an independent alarm system...
  • Page 5: Ordering Information

    Be sure that device will not fall while doing the montage. It is your responsibility if this equipment is used in a manner not specified in this instruction manual. Report any shortage or damage to your local sales office as soon as possible. ENG EGG HATCHER 02 V01 04/16...
  • Page 6: General Description

    2.1 General Description 2.2 Front View, Dimensions and Panel Cutout of EGG HATCHER ENG EGG HATCHER 02 V01 04/16...
  • Page 7 ENG EGG HATCHER 02 V01 04/16...
  • Page 8: Mounting

    2 – Insert the mounting clamps to the holes that located top and bottom sides of device and screw up the fixing screws until the unit completely immobile within the panel ENG EGG HATCHER 02 V01 04/16...
  • Page 9: Electrical Wiring Diagram

    2.4 Electrical Wiring Diagram Electrical Wiring Diagram for Pronem Type Input Card ENG EGG HATCHER 02 V01 04/16...
  • Page 10 Electrical Wiring Diagram for mA Type Input Card ENG EGG HATCHER 02 V01 04/16...
  • Page 11: Main Operation Screen And General Descrption

    When any alarm is occurs, the alarm definetion is showed in this label. Used to access Menu page Used to silence the buzzer. Used to start the hatchig time. Used to stop the hatching time Used to access second working page ENG EGG HATCHER 02 V01 04/16...
  • Page 12: Second Working Page

    8 – Humidifier Alarm/Water Spray Realy output status 9 – Humidifier Relay output status Hatching time is showed as a day, hours and minute in label which is bottom of Input/output status label. Used to return Main Operation Page ENG EGG HATCHER 02 V01 04/16...
  • Page 13: Menus

    Used to start manual Tray rotation. 3.3. Menus Shutter Control Settings Advanced Settings Logs Alarms Language Selection ENG EGG HATCHER 02 V01 04/16...
  • Page 14: Button Definetions

    Return button: Used to go back to previous menu and to cancel parameter's change. Alarm button: Used to suspend alarms. Erase button: Used to erase logs on the screen. ENG EGG HATCHER 02 V01 04/16...
  • Page 15: Shutter Control

    4. MANUAL SHUTTER CONTROL Shutter control manual/automatic selection is can be made in this page. If shutter control is selection as a manual, shutter status is can be adjusted manualy. ENG EGG HATCHER 02 V01 04/16...
  • Page 16: Settings

    Temp. Filter Value:(Default = 100) Temperature filtering coefficiant factor. This parameter is can be adjusted from 1 to 300. Hum. Filter Value:(Default = 1) Humdity filtering coefficiant factor. ( not activated yet) Change Password:(Default = 0000) It is used to access to user password changing screen. ENG EGG HATCHER 02 V01 04/16...
  • Page 17: Advanced Settings

    ADVANCED SETTINGS These following pages can be accessed via Advanced Settings Menu: Control Parameters Device Settings Calibration ENG EGG HATCHER 02 V01 04/16...
  • Page 18: Control Parametres

    Buzzer Active Time(min)(Default =1): Buzzer active time can be define with this parameter. It can be adjusted from 1 to 99 minutes. When this parameter is 99, if increment button is pressed, (---) is observed. In this condition buzzer is active till buzzer silence button is pressed ENG EGG HATCHER 02 V01 04/16...
  • Page 19 This parameter value is adjusted from 1 to 30 000 rpm. When this parameter value is 1, if decrement button is pressed, 'OFF' is observed. In this time Fan speed alarm is passive. OutTemp Offset: (Default = 0) This parameter is can be adjusted from -12.0°C to 12.0°C ENG EGG HATCHER 02 V01 04/16...
  • Page 20: Temperature Parameters

    The below parameters is can be used If temperature control selection parameter is selected as a 'PID'. Proportionally (Proportional Control Parameter)(Default =50): This parameter is can be adjusted form 0 to 100 value. Integral(Integral Parameter)(Default =1000): This parameter is can be adjusted from 0 to 3600 value. ENG EGG HATCHER 02 V01 04/16...
  • Page 21: Humidity Parameters

    This parameter is can be adjusted from 1 to 10 %RH. Scale (Default =Scale2) This parameter is active only if analogue inputs type is selected as a universal (EGG HATCHER X/20.X.X.X). Parameter value is can be adjusted as a cale1: 0-20mA,...
  • Page 22: Temperature Alarm Parameters

    0 to 99 minutes. Starting Alrm Delay(minute)(Default =0): When power is first applied to the device, this time delay must be expired for activation of temperature alarm. It can be adjusted from 0 to 99 minutes. ENG EGG HATCHER 02 V01 04/16...
  • Page 23 0 to 99 minutes. Starting Alrm Delay(minute)(Default =0): When power is first applied to the device, this time delay must be expired for activation of temperature alarm. It can be adjusted from 0 to 99 minutes. ENG EGG HATCHER 02 V01 04/16...
  • Page 24: Water Spray Parameters

    For changing parameter value first press to ENTER button and hour value is can be adjusted with increment and decrement buttons, after second press to ENTER button minute value is can be adjusted with increment and decrement button, after third press to ENTER button parameter value is saved. ENG EGG HATCHER 02 V01 04/16...
  • Page 25: Shutter Parameters

    This parameter is can be adjusted from 5 to 600 second. Step Time(%)(Default =1): Minimum movement steps of shutter while opening or closing are determined as % ratio. This parameter is can be adjusted from 0.1 ile 20.0 % ENG EGG HATCHER 02 V01 04/16...
  • Page 26: Tray Rotation Parameters

    For changing parameter value first press to ENTER button and hour value is can be adjusted with increment and decrement buttons, after second press to ENTER button minute value is can be adjusted with increment and decrement button, after third press to ENTER button parameter value is saved. ENG EGG HATCHER 02 V01 04/16...
  • Page 27: Hatching Parameters

    This parameter value is can beadjusted from -2 to 0 day. Period (day)(Default =1): Hatching period time is adjusted via this parameter. This parameter value is can be adjusted from 0 to 365 day. ENG EGG HATCHER 02 V01 04/16...
  • Page 28: Device Settings

    6.2 DEVICE SETTINGS 6.2.1 Date & Time Settings When you return back to previous page, settings are registered. ENG EGG HATCHER 02 V01 04/16...
  • Page 29: Update Software

    1. Insert the flash drive that contains EGGBMP_Vxx.txt file, into the USB port. 2. Restart the HMI device by making power off and on. Note: Formatting options of USB disk must be as fallow File System: FAT 32 Allocation Unit Size 4096 bytes Quick Format: Passive ENG EGG HATCHER 02 V01 04/16...
  • Page 30: Default Settings

    6.2.3. Default Settings This section is used to return default settings back. 6.2.4. Change Password This section is to change Technician Password. ENG EGG HATCHER 02 V01 04/16...
  • Page 31: Logs

    Events occurs related Process control Incubation Period Finish • Events occurs when sensors became broken. Pronem Break(for Pronem type input card) • Communication Error: This event occurs when communication between HMI and main control card has gone down. ENG EGG HATCHER 02 V01 04/16...
  • Page 32: Alarms

    Alarm occurs related Process control Incubation Period Finish • Alarm occurs when sensors became broken. Pronem Break(for Pronem type input card) • Communication Error: This alarm occurs when communication between HMI and main control card has gone down. ENG EGG HATCHER 02 V01 04/16...
  • Page 33: Language Selection

    9. LANGUAGE SELECTION ENG EGG HATCHER 02 V01 04/16...
  • Page 34: Alarm Types

    Process Value (SET - ALARM SET) (SET + ALARM SET) Range Alarm Alarm Output Process Value (SET - ALARM SET) (SET + ALARM SET) = Process Set value = Hysteresis value for Alarm output ENG EGG HATCHER 02 V01 04/16...
  • Page 35 Analog Output : 0-20mA, 0-10V (maximum 10 mA) Relay Output : Resistive Load 5A@250VV (Electrical Life : 100.000 operation – Full Load) SSR Output: PNP(Source) type transistor output (Maximum 1A@24V Z) Display : 320x240 pixel TFT LCD Approvals : CE, EAC ENG EGG HATCHER 02 V01 04/16...