ATTACH THE REMOTE
CONTROLLER
MOUNTING
BRACKET
1. Use the two screws supplied with the controller to attach the
Mounting Bracket to the wall in the location selected by the
customer (see Fig. 10 ).
2. Install batteries in the remote control.
3. Place remote control into remote control Mounting Bracket.
4. For remote control operation, refer to the unit O,a_er's
Manual.
.... REMOTE
CONTROL
/
I
[
REMOTE
CONTROL
MOUNTING
BRACKET
Fig. 10 m Attach
Mounting
Bracket to the Wall
(OPTIONAL)
Fig. 11 mWall
Mounted
Unit - RTX
Outdoor
Unit Installation
NOTE:
The outdoor unit must be installed on a solid surface
0nounting base).
1. Place the rubber absorption cushions (supplied with the
outdoor unit) under the unit's feets to prevent vibrations.
2. Fasten the outdoor unit legs to the mounting base, as shown
in Fig. 12. The cushion goes between the legs and the
mounting base.
3. Be sure that the unit is leveled.
MAKE REFRIGERANT PIPING CONNECTIONS (OUTDOOR
UNIT)
To connect the refrigerant lines:
Use only "L" type sealed, dehydrated copper reliigerant tub-
ing. No other type of tubing may be used. Use of other types of
tubing will void the lnanufacturer's warranty.
Do not open service valves or remove protective caps from
tubing ends until all the connections are made.
Bend robing with special bending tools to avoid the forlna-
tion of sharp bends. Take care to avoid kinks or flattening of the
tubing.
Keep the tubing tree of dirt, sand, moisture, and other con-
taminants to avoid damaging the refrigerant system.
Avoid sags in the suction line to prevent the formation ofoil
traps.
Insulate
each tube with 3/8-in.
walled
thermal
pipe insu-
lation.
Inserting
the tubing
into the insulation
before
making
the connections
will save time and improve
installation
The suc-
tion and mixed-phase
lines should
never come in direct
contact.
INTER UNIT
TERMINAL BLOCK
POWER
SUPPLY
TERMINAL
BLOCK
HIGH/LOW
VOLTAGE
METAL
BARRIER
TH3
SENSOR
(HEAT PUMP
ONLY)
METAL
CONDUIT
CONNECTION
PLATE
POWER
SUPPLY
CABLE
INTER
UNIT CABLE
4 ABSORPTION
CUSHION
TO
BE PUT UNDER
EACH
FEET
Fig. 12 -- Legs Mounting
Base and Wiring
Outdoor
Units Models:
38BNC/BNQ
012, 018