WIRE THE INDOOR
UNIT
1. Strip the cables back 1/4 inch.
2. Remove the unit's fiont panel by lifting the lower part and
pulling it gently outward and upward. See Fig. 6.
3. Remove the two screws t?romthe control box cover and take
off the cover. See Fig. 7. Save the screws to reassemble.
NOTE: In general wiring the indoor unit does not require the
removal of the grille fiame but in case of need do as t\_llow:
4. Remove the two screws from the air discharge opening.
Save the screws to reassemble. See Fig. 7A.
Pull downwards and outwardston the bottom of the _itle
and gently raise the frame of the top of the unit.
Once all covers are off; mount the unit onto the wall
mounting bracket. See Fig. 8.
NOTE: Leave covers off until after the Making Drainage Con-
nections section.
Route the interconnecting unit's electric cable and the
outdoor sensor cable towards the lower right hand corner of
the indoor unit.
Make sure that the wires are connected in accordance with
the wiring diagram on the inside of the unit front cover or
within this instruction manual.
Secure the control cables to the strain relief.
For heat pump systems only, connect the outdoor sensor
TH3 to its mating black terminal. See Fig. 9.
Make sure that all wires and screws are firmly thstened. Loose
wires or connections
can cause damage and present a tire
hazard.
MAKE DRAINAGE
CONNECTIONS
1. Connect the unattached end of the drainage tube to the
drainage hose outlet.
2. Seal the drainage connection to prevent leakage.
3. Make sure there are no kinks, "U" bends or flattened sections
in the tube.
4. Check that the drainage functions properly. Fill the pan below
the unit's coil with water and obsel-ve that it fieely drains out.
5. Make sure the drainage hose is at the bottom side of the walt
through-hole (see Fig. 5).
REASSEMBLE
1. Connect the display connector to the display panel printed
circuit board.
2. Put the control box cover and _ille fiame back on using the
appropriate screws (Steps 3 and 4 of Wire the Indoor Unit
section). Put the grille insert back on.
Fig. 6 m Remove
Grille Insert
Fig. 7 m Remove
Control Cover
Fig. 7A - Remove the screws from the air
discharge
opening.
Mount the indoor unit on the mounting
bracket
©
Gently push with the arrow direction
Fig. 8 _ Indoor
Unit Mounting
Standard
Dip Switches
status from the factory
HEAT PUMP
Model-0t2
DIP Switches location
(on the ( ontrol Box side)
HEAT
PUMP
Models-009,018
DIP Switches
location
(on the Control
Box side)
COOLING
ONLY
Model-0t2
DIP Switches
location
(on the ( ontrol
Box side)
COOLING
ONLY"
Models-009,018
DIP Switches
location
(on the ( ontrol
Box side)
Inter unit
terminal
block
30VDC
Display
Connection
TH1
123456
TH3
(Heat Pump Only)
\
Inter unit cable clamp
Fig. 9 -- Outdoor
Sensor Connection