Self-diagnosis with faults:
A continuous beep or three successive
beeps sound.
A continuous beep signals a fault in the
electronics or a battery connected with the
incorrect polarity.
● Turn the ignition key to the "engine off"
position. (
8.1)
● Check the polarity of the battery
connections and connect the wiring
correctly if necessary. (
● Repeat self-diagnosis.
If the continuous beep continues to
sound even after the battery is correctly
connected, an electronic fault is
present. Consult your specialist dealer;
STIHL recommends STIHL specialist
dealers.
Three successive beeps signal a fault in
the electrics (short circuit) or in the seat
switch. It is not possible to start the engine.
RT 6112 C, RT 6112 ZL, RT 6127 ZL:
The relevant symbols and the text ERROR
flash on the display.
● Turn the ignition key to the "engine off"
position. (
8.1)
● Have a detailed diagnosis carried out
by a specialist dealer. STIHL
recommends STIHL specialist dealers.
9.2 Ride-on mower faults during
operation
The electronics monitor the safe condition
during operation. Three successive beeps
sound if there is a fault in the electrics
(short circuit, loose connectors, broken
wire).
28
The engine is stopped – the respective
symbol and the text "ERROR" flash on the
display on the models RT 6112 C,
RT 6112 ZL, RT 6127 ZL.
Behaviour:
● Turn the ignition key to the "engine off"
position. (
● Activate self-diagnosis. (
If the fault cannot be rectified,
detailed diagnosis is necessary.
15.19)
Consult your specialist dealer;
STIHL recommends STIHL
specialist dealers.

9.3 Electronics faults

In rare cases, electronics faults may occur
during operation of the mower. A
continuous beep sounds and the engine is
stopped.
Behaviour:
● Turn the ignition key to the "engine off"
position. (
● Activate self-diagnosis. (
● Restart the engine. (
If the fault cannot be rectified,
detailed diagnosis is necessary.
Consult your specialist dealer;
STIHL recommends STIHL
specialist dealers.
10. Display on the
RM 6112 C, RM 6112 ZL,
RM 6127 ZL
Faults, operating information and active
functions are shown on the display.
8.1)
9.1)
8.1)
9.1)
13.2)
The display is protected against
damage (e.g. due to water) on
account of its design. It may be
affected by fogging due to
temperature variations and high air
humidity. After the ride-on mower
has been started, ingressed
moisture dissipates within a few
minutes under the influence of heat
from the engine.
1
5-digit segmental display (
2
Set button (
10.2)
3
Mode button (
10.3)
Faults (
10.4)
4
Engine oil pressure too low
(RT 6127 ZL)
5
Battery fault
Operating information (
6
Reverse mowing
7
Driver's seat unoccupied
8
Grass catcher box open or missing
9
Fuel reserve
10
Grass catcher box full
11
Parking brake engaged
0478 192 9809 A - EN