2.3

PREPARING YOUR KAIVAC FOR USE

1.
Fill machine with clean, cool water.
2. Prepare the cleaning solution you will be
using by attaching the chemical feed line
and cap to the top of your chemical bottle
and selecting the proper metering tip. (See
placard for metering tip information)
3. Check machine for all tools and supplies
needed to complete task. See "Tool
Arrangement" in Section 2.2 of this manual.
4. If using a cleaning product that has high
foaming use a foam inhibitor to cut down on
foam. Pour 2 capfuls of inhibitor in the vac
hose with vac running to coat inside of hose.
5. Check all hoses and spray lines for damage
prior to use. If damage is found, do not con-
tinue until proper repairs are completed.
6. Plug in machine and test GFCI (Ground
Fault Circuit Interrupter) to ensure it is work-
ing properly. You are now ready.
*Applicable to all units, but KV1700 Series shown for illustration