High Efficiency Ratings
MODEL: YCIV0590E/V
LCWT
25.0
(°C)
KWi
KWi
COP
525.0
123.1
3.9
5.0
539.7
124.0
3.9
6.0
554.7
125.0
4.0
7.0
569.9
126.1
4.1
8.0
585.2
127.1
4.2
9.0
600.7
128.2
4.2
10.0
616.4
129.2
4.3
11.0
632.2
130.3
4.4
12.0
648.3
131.3
4.5
13.0
MODEL: YCIV0630E/V
LCWT
25.0
(°C)
KWi
KWi
COP
558.7
129.2
3.9
5.0
574.5
130.1
4.0
6.0
590.5
131.1
4.0
7.0
606.9
132.2
4.1
8.0
623.5
133.4
4.2
9.0
640.4
134.6
4.3
10.0
657.7
136.0
4.4
11.0
675.2
137.4
4.4
12.0
693.1
139.0
4.5
13.0
MODEL: YCIV0700E/V
LCWT
25.0
(°C)
KWi
KWi
COP
621.1
143.4
3.9
5.0
638.5
144.3
4.0
6.0
656.2
145.3
4.1
7.0
674.1
146.4
4.1
8.0
692.3
147.7
4.2
9.0
710.7
149.0
4.3
10.0
729.4
150.5
4.4
11.0
748.4
152.0
4.4
12.0
767.7
153.7
4.5
13.0
NOTES:
1.
kWo
=
Unit kW Cooling Capacity Output
2.
kWi
=
Compressor kW Input
3.
COP
=
Coefficient of Performance (includes condenser fan power)
4.
LCWT
=
Leaving Chilled Water Temperature
5.
Ratings based on 0.168 l/s cooler water per ton, and 0.018 (m
6.
ARI 550/590 does not provide certification for 50Hz ratings. The unique use of the YCIV variable speed drive allows compressor operation at the output speed regardless of the input
power frequency. This allows for common unit/heat exchanger configurations between 60Hz and 50Hz with closely matching capacity.
36
AIR TEMPERATURE ON - CONDENSER (°C)
30.0
KWi
KWi
COP
KWi
515.6
139.0
3.4
503.3
530.4
140.2
3.5
518.1
545.4
141.3
3.5
533.0
560.7
142.4
3.6
548.1
576.2
143.5
3.7
563.5
591.8
144.7
3.7
579.1
607.7
145.8
3.8
594.9
623.8
147.0
3.9
610.9
640.1
148.3
4.0
627.2
AIR TEMPERATURE ON - CONDENSER (°C)
30.0
KWi
KWi
COP
KWi
550.3
147.1
3.4
540.3
565.7
147.9
3.5
555.3
581.5
148.8
3.6
570.6
597.5
149.7
3.6
586.3
613.9
150.7
3.7
602.3
630.5
151.8
3.8
618.5
647.5
153.0
3.9
635.1
664.8
154.3
3.9
652.0
682.3
155.6
4.0
669.2
AIR TEMPERATURE ON - CONDENSER (°C)
30.0
KWi
KWi
COP
KWi
611.6
164.1
3.4
600.1
628.9
164.8
3.5
617.0
646.4
165.6
3.5
634.2
664.2
166.5
3.6
651.7
682.2
167.5
3.7
669.4
700.4
168.6
3.8
687.3
719.0
169.8
3.9
705.6
737.8
171.1
3.9
724.1
756.9
172.4
4.0
742.9
– °C)/kW
2
–.
.
SI - 400V/50Hz
35.0
40.0
KWi
COP
KWi
KWi
156.2
3.0
487.8
176.4
157.4
3.0
500.9
177.3
158.5
3.1
514.0
178.2
159.7
3.2
527.2
179.1
161.0
3.2
540.5
180.0
162.2
3.3
554.0
180.9
163.5
3.4
567.6
181.9
164.8
3.4
581.2
182.9
166.2
3.5
595.0
183.8
35.0
40.0
KWi
COP
KWi
KWi
167.0
3.0
525.1
189.7
167.8
3.0
538.7
190.4
168.6
3.1
552.7
191.0
169.5
3.2
566.8
191.7
170.4
3.3
581.3
192.4
171.4
3.3
596.0
193.1
172.5
3.4
610.9
193.9
173.6
3.5
626.1
194.7
174.8
3.5
641.6
195.5
35.0
40.0
KWi
COP
KWi
KWi
187.0
3.0
582.8
211.7
187.7
3.0
598.1
212.0
188.4
3.1
613.8
212.3
189.3
3.2
629.7
212.6
190.2
3.2
645.8
212.9
191.1
3.3
662.3
213.3
192.2
3.4
678.9
213.6
193.3
3.5
695.7
214.0
194.5
3.5
712.8
214.4
45.0
COP
KWi
KWi
COP
2.6
449.0
192.6
2.2
441.1
2.6
460.8
193.4
2.2
452.7
2.7
472.8
194.1
2.3
464.5
2.7
484.9
195.0
2.3
476.5
2.8
497.0
195.9
2.4
488.4
2.9
509.5
196.8
2.4
500.6
2.9
522.3
197.7
2.5
513.2
3.0
535.2
198.6
2.5
525.9
3.0
548.3
199.5
2.6
538.8
45.0
COP
KWi
KWi
COP
2.6
492.2
209.6
2.2
484.3
2.6
504.1
210.2
2.2
496.2
2.7
516.4
210.7
2.3
508.1
2.7
528.8
211.3
2.3
520.3
2.8
541.5
211.8
2.4
532.8
2.9
554.4
212.3
2.4
545.5
2.9
567.6
212.9
2.5
551.5
3.0
580.9
213.4
2.5
557.2
3.1
594.4
214.0
2.6
562.8
45.0
COP
KWi
KWi
COP
2.6
547.1
228.0
2.2
538.6
2.6
560.8
228.4
2.3
552.0
2.7
574.6
228.7
2.3
565.6
2.7
588.8
229.0
2.4
579.5
2.8
603.2
229.2
2.5
593.7
2.9
617.8
229.4
2.5
608.1
3.0
632.7
229.6
2.6
622.8
3.0
647.8
229.7
2.6
632.7
3.1
663.1
229.9
2.7
638.4
JOHNSON CONTROLS
46.0
KWi
KWi
COP
196.0
2.1
196.7
2.2
197.5
2.2
198.2
2.3
199.1
2.3
200.0
2.4
200.9
2.4
201.8
2.4
202.7
2.5
46.0
KWi
KWi
COP
213.4
2.1
213.9
2.2
214.6
2.2
215.1
2.3
215.7
2.3
216.2
2.4
211.4
2.4
206.6
2.5
202.0
2.6
46.0
KWi
KWi
COP
230.9
2.2
231.3
2.2
231.6
2.3
232.0
2.3
232.2
2.4
232.4
2.4
232.6
2.5
229.6
2.6
224.0
2.7