Product Nomenclature - York BP 036 Technical Manual

Single package heat pump units
Table of Contents

Advertisement

255027-YTG-B-0507

PRODUCT NOMENCLATURE

B P 048 C00 A 2 A AA 1 0 1 2 4 A
Product Category
B = HP, Single Pkg., R-22
Product Identifier
P = 13.0 SEER HP
Nominal Cooling Capacity
036 = 3.0 Ton
048 = 4.0 Ton
060 = 5.0 Ton
072 = 6.0 Ton
Heat Type and Nominal Heat Capacity
C00 = Cooling Only. Suitable for Field
Installed Electric Heat
Electric Heat Options
E05 = 5 KW
E07 = 7 KW
E10 = 10 KW
E15 = 15 KW
E20 = 20 KW
E30 = 30 KW
Airflow
A = Direct Drive
B = Direct Drive/Single Input Economizer
D = Direct Drive/Motorized Damper
N = Belt Drive
P = Belt Drive/Single Input Economizer
R = Belt Drive/Motorized Damper
Unitary Products Group
Product Generation
1 = First Generation
AA = None
AB = Phase Monitor
AC = Coil Guard
AD = Dirty Filter Switch
AE = Phase Monitor & Coil Guard
AF = Phase Monitor & Dirty Filter Switch
AG = Coil Guard & Dirty Filter Switch
AH = Phase Monitor, Coil Guard & Dirty Filter Switch
AS = Bottom Drain Connection
RC = Coil Guard & American Flag
TA = Technicoat Condenser Coil
TJ = Technicoat Evaporator Coil
TS = Technicoat Evaporator and Condenser Coil
Voltage
1 = 208/230-1-60
2 = 208/230-3-60
4 = 460-3-60
ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be
5 = 575-3-60
located in digits 15-18.
Installation Options
A = No Options Installed
B = Option 1
C = Option 2
D = Options 1 & 2
E = Option 3
F = Option 4
G = Options 1 & 3
H = Options 1 & 4
J = Options 1, 2 & 3
K = Options 1, 2, & 4
L = Options 1,3 & 4
M = Options 1, 2, 3, & 4
N = Options 2 & 3
P = Options 2 & 4
Q = Options 2, 3, & 4
R = Options 3 & 4
S = Option 5
T = Options 1 & 5
U = Options 1, 3, & 5
V = Options 1, 4, & 5
W = Options 1, 3, 4, & 5
X = Options 3 & 5
Y = Options 4 & 5
Z = Options 3, 4 & 5
Options
1 = Disconnect
2 = Non-Pwr'd Conv. Outlet
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet
Product Style
A = Style A
Configuration Options (not required for all units)
These four digits will not be assigned until a quote is requested, or an order placed.
SS Drain Pan
CPC Controller, DFS, APS
Johnson Controller, DFS, APS
Honeywell Controller, DFS, APS
Novar Controller, DFS, APS
Simplicity IntelliComfort Controller
Simplicity IntelliComfort Controller w/ModLinc
2" Pleated filters
BAS Ready Economizer (2-10 V.D.C. Actuator without a Controller)
Any Combination of Additional Options that Don't Have an Option Code Pre-assigned
Additional Options
Standard Cabinet
Hinged Filter Door & Toolless Access Cabinet
BA = Hinged Filter Door & Toolless Access Panels
BB = Phase Monitor, Hinged Filter Door & Toolless
BC = Coil Guard, Hinged Filter Door & Toolless
BD = Dirty Filter Switch, Hinged Filter Door &
BE = Phase Monitor & Coil Guard, Hinged Filter
BF = Phase Monitor & Dirty Filter Switch, Hinged
BG = Coil Guard & Dirty Filter Switch, Hinged Filter
BH = Phase Monitor, Coil Guard & Dirty Filter Switch,
Access Panels
Access Panels
Toolless Access Panels
Door & Toolless Access Panels
Filter Door & Toolless Access Panels
Door & Toolless Access Panels
Hinged Filter Door & Toolless Access Panels
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bp 048Bp 060Bp 072

Table of Contents