Search For New Hardware; Controller Standby; Controller Reboot; Quit - Art ARTTRACK1 System User Manual

Table of Contents

Advertisement

8.4.4 Search for new hardware

Without the need of restarting the controller you can dynamically analyse your system
for changes in configuration (e.g. added or removed cameras,
Therefore proceed as follows:
connect a new camera to the controller
wait until the camera has finished booting
within
DTrack2
press 'F2' to perform a search for new hardware
check if the camera has been recognized successfully (e.g. by opening camera
settings
'F7
')
start the measurement, the message '(re-)calibration required!' should appear in
red color inside the
8.3.3.1 on page 135 for details)
perform a room re-calibration 8.6.3.3 on page 170, added cameras are automatically
marked as 'moved' in the room re-calibration dialogue.
DTrack2
for best performance it is highly recommended to perform a recalibra-
tion

8.4.5 Controller standby

Force the controller to go into standby mode with this command. You can restart the
controller manually or by using Wake On LAN. Please refer to chapter 8.2.3 on page 126
for more details.

8.4.6 Controller reboot

Reboot the controller with this command.

8.4.7 Quit

Quit
DTrack2
frontend software. In case the system is still in measurement mode, a
confirmation window will show up. You may leave the active measurement running, the
frontend software will quit anyway.
Monitor 2DOF display
is able to operate when cameras have been added or removed;
ART
of the corresponding camera (see chapter
8.4 Menu DTrack2
radio transceiver).