Advertisement

Quick Links

User Manual
Copyright © 2011 - 2020 Opgal LTD, all rights reserved.
The data contained in this document is proprietary to Opgal LTD. It is disclosed to the
receiving party only for the sole purpose stated herein, and shall not be disclosed by the
receiving party to any third party, and shall not be duplicated, used or disclosed in whole
or in part for any purpose other than the purpose specifically stated. This publication, or
any parts thereof, may not be reproduced in any form without the express written
permission of Opgal LTD.

Advertisement

Table of Contents
loading

Summary of Contents for OPGAL Therm-App MD Pro

  • Page 1 Copyright © 2011 - 2020 Opgal LTD, all rights reserved. The data contained in this document is proprietary to Opgal LTD. It is disclosed to the receiving party only for the sole purpose stated herein, and shall not be disclosed by the receiving party to any third party, and shall not be duplicated, used or disclosed in whole or in part for any purpose other than the purpose specifically stated.
  • Page 2: Table Of Contents

    Setting Auto IP Addresses and DNS Server Addresses (DHCP) ............. 13-19 13.1.3. Setting Manual DNS Server Addresses ..................13-19 13.1.4. HTTPS Connection Section......................13-20 13.2. Certificates Tab ..........................13-21 SYSTEM ..............................14-24 14.1. ADMIN ............................14-24 Page 1-2 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 3 Upgrading and Coupling a Therm-App MD BASIC Camera to PRO version System Computer ....15-32 Specification ............................16-36 Computer Main Features ........................17-37 Terms and Conditions ..........................18-39 Contact Information: ............................18-1 Page 1-3 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 4: Contents

    Before use, make sure the following are included in the package. If anything is missing, contact your dealer. • Computer Unit • Thermographic Camera including lens 6.8mm • Power supply • USB to micro USB cable • HDMI cable • Power cable • Mini Tripod. Page 1-4 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 5: Therm-App Md™ Pro User Manual

    Do not expose the system to extremely high or low temperatures • Mount the camera only on a tripod using a quarter inch screw of with the adjustable clamp • Do not expose the system to direct sunlight Page 2-5 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 6: Computer Description

    OS FLASH Special micro USB input for a technician’s use only. Warning! Do not use this port unless specifically instructed to do so by an OPGAL technical manager. Micro SD A saving media option – for future use. (currently not available).??? GPIO A physical 3.3v TTL output for triggering alerts such as buzzer/flashlight...
  • Page 7: System Overview

    Therm-App MD™ Pro User Manual 4. System Overview Therm-App MD™ PRO is Opgal’s thermographic imaging device for elevated body temperature (EBT) measurement, specifically calibrated to measure temperature. The Therm-App MD™ PRO sensor is based on QVGA, α- Si bolometer 17µ ,384x288 pixels.
  • Page 8: Tips And Recommendations

    7.5. Establishing a Baseline To establish a baseline and to begin measurement, the Therm-App MD™ PRO needs at least 30 individuals to pass in front of the camera. Page 7-8 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 9: Getting Started

    Therm-App MD™ Pro User Manual 8. Getting started Therm-App MD Pro can be operated in two operation modes: Remote mode, by connecting the system’s computer through a LAN to a remote PC; or Kiosk mode by connecting HDMI LCD monitor, keyboard and mouse directly to the computer system.
  • Page 10: Browser Support

    Select Use the following IP address and fill in the IP address, Subnet mask and the Default gateway as shown in the example below. Open Google Chrome™ browser and enter the IP address. The default IP address is 192.168.0.100 Page 10-10 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 11 It is recommended to set a secure password for the Administrator account. The live view page will open in your browser. After creating the Administrator username and password the following login screen will be displayed. Page 10-11 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 12: First Time Turning On

    A live B&W video and a ‘Camera is warming up…’ message will appear. Only when the warm up ends, the system is ready for use. Page 11-12 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 13: Webpage Overview

    Quick access menu Voice Alarm Is Disable Voice Alarm Is Enable Reference ROI Color Palette Take a Snapshot Full Screen live view Settings Hide Detection Show Detection About Page 12-13 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 14: Reference Roi

    Therm-App MD™ Pro User Manual 12.1. Reference ROI The Therm-App MD Pro has an optional Reference ROI to improve performance in locations with unstable ambient temperature. The reference ROI allows you to select a STABLE AREA to enable the camera to perform steadily. This will allow the camera’s advanced algorithm to monitor sudden changes in the ambient temperatures and offset...
  • Page 15: Color Palette

    Therm-App MD™ Pro User Manual 12.2. Color Palette NONE GREEN INFERNO RAINBOW LAVA IRON VIRIDIS Page 12-15 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 16: Settings

    Allows you do define the minimum temperature to display. Max display temperature [35, 60(Auto] (°c): Allows you do define the maximum temperature to display. Orientation: Allows you do define the camera orientation. Page 12-16 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 17: Main Settings Menu

    Main settings menu When pressing on the Hamburger icon on the left upper corner the left menu will pop up. Pressing on THERM- APP MD PRO will close this menu. Page 13-17 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 18: Network

    To change and set the IP addresses and DNS server addresses, press on IP ADDRESSES button. The following window will appear. Change the IP address and press APPLY to save, or CANCEL to dismiss the changes. Page 13-18 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 19: Setting Auto Ip Addresses And Dns Server Addresses (Dhcp)

    Enter the DNS server address by either using the buttons which appear when hovering over the empty fields or by typing values into the fields using the keyboard. Page 13-19 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 20: Https Connection Section

    Set the HTTPS Port slider to the desired value (1 to 65535). Note: The HTTPS Port default value is 443. Press APPLY to save or CANCEL to dismiss the changes. Page 13-20 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 21: Certificates Tab

    Common Name (enter an IP address or system host name; required) • State or Province • Country (selected list) • City • Organization • Department and then press SUBMIT for approval. Page 13-21 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 22 • State or Province • Country (select from the drop-down list) • City • Organization • Department • Validity (number of days) and then press SUBMIT for approval. Page 13-22 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 23 Select Upload Certificate for loading an existing Secure Sockets Layer (SSL) certificate which originated from another source. Press SELECT CERTIFICATE and browse to select certificate file (*.pem format). Then, press SUBMIT to submit the uploaded certificate. Page 13-23 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 24: System

    • Press RESTART to reboot the system. • Press ARCHIVE SYSTEM FILES to create system files for sending to Opgal technical support. • Press EXPORT SITE to export site defaults with constant IP address or with DHCP properties. A compressed file in. tgzx format is downloaded to the computer’s Download folder.
  • Page 25: Date And Time

    Select Synchronizing with the browser time to sync the system with browser time. Select Synchronizing with NTP to sync the system with NTP by 3 ways: Automatically, by name, by IP address. Page 14-25 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 26: File Upload

    FILE UPLOAD Press SELECT FILE button to update a new firmware and browse to the relevant firmware file location. Select the file and press on the OPEN button. Page 14-26 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 27 Therm-App MD™ Pro User Manual Then press on the UPLOADFILE button to upload new version. Look at the process BAR Page 14-27 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 28 Therm-App MD™ Pro User Manual Press RESTART to reboot the system Page 14-28 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 29 Therm-App MD™ Pro User Manual You can check if you are using the most updated version of the Therm-App MD PRO by pressing on the i icon Page 14-29 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 30: Users

    Therm-App MD™ Pro User Manual 14.1.3. USERS When entering the USERS tab as an admin you can manage users by adding, removing and editing user accounts. Page 14-30 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 31: Support

    Therm-App MD™ Pro User Manual 14.1.4. SUPPORT Special tab for Opgal technicians only Page 14-31 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 32: Upgrading And Coupling A Therm-App Md Basic Camera To Pro Version System Computer

    5) Connect the power supply to turn ON the system. 6) The system will bootup and will display the FIRST TIME SETUP screen. 7) Create an administrator account and password and press on the ADD button. Page 15-32 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 33 8) The system will try to couple and calibrate the camera to the computer and the following screen will be displayed. 9) After few minutes the system may display a Setup Error message. If so follow the steps describes in section 10 bellow. Page 15-33 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 34 Obtain IP address automatically. b) Obtain DNS Servers automatically. 11) Press on the APPLY button. 12) From the popup System Restart menu press RESTART. 13) The System will restart and a “Getting Calibration” screen will appear. Page 15-34 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 35 15) After few minutes a live B&W video and a ‘Camera is warming up…’ message will appear. 16) Wait to Camera is warming up procedure to end and you may start using the system. Page 15-35 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 36: Specification

    Proprietary USB video Operating Temperature 10°C to +45°C (14°F to +122°F) Storage Temperature -20°C to +60°C (-4°F to +140°F) Certifications & Encapsulation CE, FCC, IP54, TAA, TSA, NDAA Section 889 Page 16-36 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 37: Computer Main Features

    Power Supply & Consumption 12VDC w/ 2-pin terminal block, 15W @airflow 0.5m/sec Mounting Wallmount Dimensions (W x D x H) 88mm x 75mm x 39mm (3.39” x 2.87” x 1.3”) Page 17-37 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 38 Net Weight 0.4 Kg (0.88 lb) Operating Temperature 10°C to +40°C (14°F to +104°F) Storage Temperature -45°C to +80°C (-49°F to +176°F) Certifications & Encapsulation CE, FCC Class A Page 17-38 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 39: Terms And Conditions

    Date (“Warranty Period”). Any Product that is repaired or replaced under warranty, is covered for nighty (90) days from the date of return shipment by Opgal or for the remaining duration of the applicable Warranty Period, whichever is longer. If the Product is purchased in an EU country, to the extent you are a Consumer, you have an additional year (according to the EU-Directive 1999/44) to claim for deficiencies or malfunctioning of the Product, which were present at the time of purchase, but were not apparent then, as determined by Opgal.
  • Page 40 Your license, under Section 6 above, confers no title or ownership in the Software or the Documentation and should not be construed as a sale of any rights in the Software or the Documentation. Opgal’s third party suppliers may protect their rights in the event of any violation of these terms.
  • Page 41 Be careful when you clean the infrared lens. The lens has a delicate anti-reflective coating. Do not clean the lens too vigorously; this can damage the anti-reflective coating. Page 18-41 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 42 The Product is provided with appropriate USB-OTG cables. Use only the supplied USB OTG cables. Using any other types of cables might not work at all, may fail, and even damage the equipment. Page 18-42 of 43 Confidential Opgal Propriety Document P/N UM-TAH00AQ-MD-PRO| Rev B...
  • Page 43: Contact Information

    Contact Information: Email: info@opgal.com Phone: +972-4-9953903 Fax: +972-4-9953900 http://www.opgal.com P.O. Box 462, Industrial Area 5, Karmiel 2161401, ISRAEL All specifications are subject to change without notice Last Updated on Sep 07 2020...

Table of Contents