7.8

UPS (SMT1000I)

Item
Output
Output outlet shape
Group number of switch output outlet
Maximum output capacity
When using standard input plug
Maximum output capacity
When changing input plug
Output voltage distortion
Output frequency
during battery operation
Waveform during battery operation
Switching time (normal)
Automatic voltage adjustment
function
Input
Rated input voltage
Rated input frequency
Surge filter ・ Noise filter
Surge filter
Noise filter
Battery
Battery type
Battery capacity
Charging time up to 90%
Replacement battery kit model number
Dimension ・ Mass
External dimension
Net Mass
Packing Mass
Environment
Using environment
Audible noise at a distance of 1 m
Standard
Authorization
Interface
Port
LCD display Character-supported
Alarm
Description
IEC-320 C13 × 8
1
700W/1000 VA
700W/1000 VA
Less than 5%. (Full load)
50/60 Hz ±2%
Sine wave output
5–10 ms
Correspondence
AC230 V
50/60 Hz +/- 3Hz (Automatic detection)
Presence
Presence
Small sealed lead-acid battery
12VDC/12Ah (2pcs)
About 3 hours
RBC6
219×171×439 mm
Approx. 18.9 kg
Approx. 22.8 kg
Max height 3,000 m, humidity 0–95%,
tempurature0℃–40℃(without condensation)
Less than 41 dBA
CE, CSA, EAC, EN/IEC 62040-1, EN/IEC 62040-2, RCM, UL
1778, VDE
RJ-45 Serial, USB, SmartSlot
Correspondence
Battery operated, low battery
7-7