barbas Evolux 100-45 Installation And Maintenance Manual

barbas Evolux 100-45 Installation And Maintenance Manual

Hide thumbs Also See for Evolux 100-45:
Table of Contents

Advertisement

Quick Links

I I nstallation and
maintenance manual
Evolux 100-45
Serial number:
Production date:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Evolux 100-45 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for barbas Evolux 100-45

  • Page 1 I I nstallation and maintenance manual Evolux 100-45 Serial number: Production date:...
  • Page 2 Barbas Bellfires BV. This document could contain technical inaccuracies or typographical errors. Barbas Bellfires BV reserves the right to revise this document from time to time in the contents thereof.
  • Page 3: Table Of Contents

    5.3.8 Attach a stone bar from a third party supplier (optional)..........26 5.3.9 Final check on the appliance...................27 Maintenance..................28 Appliance........................... 28 Access to inside of door ......................28 Combustion air supply....................... 29 Convection air system........................29 Chimney.............................29 Removal of the baffles....................... 30 Place the baffles........................31 Opti-Air system ......................... 31 Evolux 100-45...
  • Page 4 Evolux 100-45 with 3-sided frame and convection casing............36 Evolux 100-45 with 3-sided frame and air box................37 Evolux 100-45 with 3-sided frame with Opti-Air and convection ventilator........ 38 Evolux 100-45 with 3-sided frame and fire screen..............39 Evolux 100-45 with 4-sided frame....................40 Evolux 100-45 with 4-sided frame and air box................41...
  • Page 5: Declaration Of Performance

    Name, registered trade name or registered trade mark Barbas Bellfires BV; Hallenstraat 17; 5531 AB Bladel; The Netherlands and contact address of the manufacturer as required pursuant to Article 11(5)
  • Page 6 Name, registered trade name or registered trade mark Barbas Bellfires BV; Hallenstraat 17; 5531 AB Bladel; The Netherlands and contact address of the manufacturer as required pursuant to Article 11(5)
  • Page 7: About This Document

    About this document About this document This document shows the necessary information to do these tasks on the Evolux 100-45: • Installation • Maintenance This document refers to the Evolux 100-45 as 'the appliance'. This document is an essential part of your appliance. Read it carefully before you do work on the appliance.
  • Page 8: Description

    Front / top view of the appliance Door handle Adjustable feet Glass Flue connector Control lever Convection air outlet Grate Fire screen handle Ash tray Frame Cast iron panels Door lock handle Primary air inlet Evolux 100-45...
  • Page 9 Description B B ottom view Heat shield (steel) Combustion air inlet Lower baffle (ceramic) Convection air inlet Upper baffle (vermiculite) Adjustable feet Secondary air inlet Chain cover Air wash inlet Evolux 100-45...
  • Page 10 Description B B ottom view with convection ventilator / combustion air inlet box Combustion air inlet Adjustable feet Convection ventilator (option) Adjustable height frame (option) Convection ventilator / Combustion Chain cover air inlet box (option) Evolux 100-45...
  • Page 11: Appliance Options

    The appliance can have an electronic combustion control system, 'Opti-Air'. This system controls the combustion at a preselected combustion level or to a set room temperature. Fire screen The appliance can have a safety screen to prevent acci- dental touching of the hot glass surface. Evolux 100-45...
  • Page 12: Intended Use

    The illustrations shown in this paragraph are typical installation examples. Installation with combustion air supply from the installation room, without convection package Combustion air inlet Insulating material Chimney breast ventilation air inlet Air supply to the room Chimney Adjustable feet Chimney breast ventilation air outlet Evolux 100-45...
  • Page 13 I I nstallation with external combustion air supply, with convection package and convection ventilator Combustion air inlet Convection air outlet Convection air inlet Chimney breast ventilation air outlet Chimney breast ventilation air inlet High adjustable feet (option) Chimney Flexible aluminum pipe (convection Insulating material set option) Evolux 100-45...
  • Page 14: Safety

    Dispose of ceramic heat-resistant glass as household waste. Do not dispose of ceramic heat-resistant glass in a glass recycling container. • Dispose of an obsolete appliance according to instructions of the authorities or the fitter. • Obey the local regulations. Evolux 100-45...
  • Page 15: Installation

    • If the appliance is equipped with a convection ventilator and/or Opti-Air, there must be 1 or 2 wall sockets with earth connection. These sockets must be accessible at all times. Evolux 100-45...
  • Page 16: Requirements On The Chimney

    The chimney outlet must be at least 1 meter above a flat roof. • The chimney outlet must be free from any objects (buildings, trees, etc.) within a horizontal range of at least 5 meter. • Make sure your fire insurance policy covers any damage caused by a chimney fire. Evolux 100-45...
  • Page 17: Preparation For Installation

    You can use the carrying tubes to move the appliance. Note: The carrying tubes are not included with the appliance. Install the appliance. Make sure the distance between the appliance and rear wall is approximately 10 cm minimum. Evolux 100-45...
  • Page 18: Horizontally Align The Appliance

    5.3.2 Horizontally align the appliance Aligning with adjustable feet Adjust the adjustable feet. Use a 13 mm fork spanner. Make sure that the appliance is installed horizontally. Use a spirit level. Evolux 100-45...
  • Page 19: Connect The Flue Gas Pipe

    Make sure that all mechanical connections of the flue system are correctly used. Make sure that all of the flue system is gas-tight, 5.3.6 Insulate any non-insulated pipes with ceramic insulation wool. Refer to for the material requirements. Evolux 100-45...
  • Page 20: Connect The External Combustion Air Supply Pipe

    Make a hole in the outer wall or floor with at least a diameter of 125 mm. Install a grate in the hole in the outer wall. A grate is not needed when the combustion air supply comes from the crawl space under the floor. Evolux 100-45...
  • Page 21: Connect The Convection Set (Optional)

    Bend out the 3 lips on the collar adaptor, to attach the collar adaptor on the inlet opening Connect a flexible aluminum pipe (B) on the collar adaptor (A). Use a hose clamp ( C). Connect the flexible aluminum pipe to a fitting box in the chimney breast Evolux 100-45...
  • Page 22 Bend out the 3 lips on each collar adaptor, to attach the collar adaptor on the outlet opening. Connect the flexible aluminum pipes (B) on the collar adaptors (A) . Use the hose clamps ( C). Connect the flexible aluminum pipes to fitting boxes in the chimney breast. 2 2 2 Evolux 100-45...
  • Page 23: Insulate The Appliance

    If the appliance is placed against a load-bearing wall or a combustible wall, put a non-combustible insulating wall with a thickness of at least 100 mm and a thermal conductivity of maximum 0.10 W/m.K before it on a distance of at least 20 mm from the combustible or load-bearing wall. Evolux 100-45...
  • Page 24 Plate of non-combustible material with a thickness of at least 40 mm and a thermal conductivity of at least 0.10 W/m.K Air gap Space between insulation plate and wall. Width of air gap at least 50 Ceiling Existing ceiling made of combustible material Evolux 100-45...
  • Page 25 Refer to for requirements on the size of the ventilation air openings. Important: Only for the optional Barbas Opti-Air system. • Make sure to put the end of the NTC temperature measurement cable near the intended location of the ventilation air inlet grate.
  • Page 26: Attach A Stone Bar From A Third Party Supplier (Optional)

    If the appliance has been ordered with the possibility to attach a stone bar from another supplier than Barbas, do the procedure to attach the stone bar on the appliance. Loosen the 2 screws that holds the stone bar adapter with a 3 mm hexagonal key.
  • Page 27: Final Check On The Appliance

    Make sure all cast iron plates and the baffles are in the correct position. If applicable: Start the convection ventilator and make sure the ventilator does not make an unusual noise (grinding sound). A soft hum is not an unusual sound. Contact your dealer if the final check shows a defect. Evolux 100-45...
  • Page 28: Maintenance

    Clean the inside of the appliance with a soft brush. Clean the metal parts on the outside of the appliance with a dry lint free cloth. Use Barbas heat resistant paint spray to repair lacquer damage. Access to inside of door Make sure the door is closed.
  • Page 29: Combustion Air Supply

    Make sure to remove the heat shield and the upper and lower baffle before the chimney sweep work. Refer to Make sure to replace the heat shield and the upper and lower baffle after the finish of the chimney sweep work and before firing the appliance. Refer to Evolux 100-45...
  • Page 30: Removal Of The Baffles

    6.6.3 Remove the upper baffle With 2 hands, hold the upper baffle at the back side. Turn the front of the upper baffle until it is in a vertical position. Move the baffle up and over the supports. Evolux 100-45...
  • Page 31: Place The Baffles

    It is recommended to change the 9 V back-up battery every year. Remove the ventilation air inlet grate. Get the battery holder and open the lid. Replace the 9 V battery and close the lid. Put the battery holder and ventilation air inlet grate back. Evolux 100-45...
  • Page 32: Technical Data

    Technical data Technical data Technical data Table 4: Technical data Evolux 100-45 Name Barbas Barbas Model Evolux 100-45 Evolux 100-45 Opt.-Air Tested in accordance with EN 13229:2001-A2:2004 EN 13229:2001-A2:2004 EN16510-1 annex D, E, F EN16510-1 annex D, E, F Energy efficiency index 99.9...
  • Page 33 • Installation and mainte- • Installation and mainte- shall be taken when the local nance manual nance manual space heater is assembled, in- • User manual • User manual stalled or maintained, are listed in the attached documents: Evolux 100-45...
  • Page 34: Connections On Opti-Air System

    NTC element (re- sistance measurement) + and - - is black wire Thermocouple connection Measures the gas temperature of the flue gasses in the appli- ance + = green wire - = white wire Evolux 100-45...
  • Page 35: Dimensions

    Dimensions Dimensions Evolux 100-45 with 3-sided frame Evolux 100-45...
  • Page 36: Evolux 100-45 With 3-Sided Frame And Convection Casing

    Dimensions 8 8 .2 Evolux 100-45 with 3-sided frame and convection casing Evolux 100-45...
  • Page 37: Evolux 100-45 With 3-Sided Frame And Air Box

    Dimensions 8 8 .3 Evolux 100-45 with 3-sided frame and air box With optional adjustable height frame 3 Combustion air inlet openings (Ø 125 mm) at the left side, right side and bottom of the air box. Evolux 100-45...
  • Page 38: Evolux 100-45 With 3-Sided Frame With Opti-Air And Convection Ventilator

    Dimensions 8 8 .4 Evolux 100-45 with 3-sided frame with Opti-Air and convection ventilator With optional adjustable height frame 3 Combustion air inlet openings (Ø 125 mm) at the left side, right side and bottom of the air box. 2 Convection air inlet openings (Ø 125 mm) at the left side and right side of the convection ventilator / combustion air box.
  • Page 39: Evolux 100-45 With 3-Sided Frame And Fire Screen

    Dimensions 8 8 .5 Evolux 100-45 with 3-sided frame and fire screen Evolux 100-45...
  • Page 40: Evolux 100-45 With 4-Sided Frame

    Dimensions 8 8 .6 Evolux 100-45 with 4-sided frame Evolux 100-45...
  • Page 41: Evolux 100-45 With 4-Sided Frame And Air Box

    Dimensions 8 8 .7 Evolux 100-45 with 4-sided frame and air box With optional adjustable height frame 3 Combustion air inlet openings (Ø 125 mm) at the left side, right side and bottom of the air box. Evolux 100-45...
  • Page 42: Evolux 100-45 With 4-Sided Frame And Convection Casing

    Dimensions 8 8 .8 Evolux 100-45 with 4-sided frame and convection casing Evolux 100-45...
  • Page 43: Evolux 100-45 With 4-Sided Frame With Opti-Air And Convection Ventilator

    Dimensions 8 8 .9 Evolux 100-45 with 4-sided frame with Opti-Air and convection ventilator With optional adjustable height frame 3 Combustion air inlet openings (Ø 125 mm) at the left side, right side and bottom of the air box. 2 Convection air inlet openings (Ø 125 mm) at the left side and right side of the convection ventilator / combustion air box.
  • Page 44: Evolux 100-45 With 4-Sided Frame And Fire Screen

    Dimensions 8 8 .10 Evolux 100-45 with 4-sided frame and fire screen Evolux 100-45...
  • Page 45: Dimensions Decorative Stone Bar

    Dimensions 8 8 .11 Dimensions decorative stone bar Make sure the dimensions of the decorative stone bar supplied by a third party supplier comply with the dimensions in the picture hereunder. Evolux 100-45...
  • Page 46: Warranty Terms

    Complaints will only be accepted if they are reported to the Barbas dealer, together with the serial number of the Barbas appliance which is stated on the front of the instructions for use. In addition, the original receipt (invoice, receipt, cash receipt) showing the date of purchase must also be submitted.
  • Page 47 Article 5: Warranty period This warranty will only be granted during the warranty period. The body of the Barbas appliance is guaranteed for a period of 10 years against construction and/or material faults, starting from the moment of purchase. For other parts of the Barbas appliance, a similar warranty applies from the moment of purchase for a period of one year.
  • Page 48 Y Y our Barbas dealer 002 - 07.10.2020 -...

Table of Contents