Gun block unit, mixing module and needle

WARNING:
Before carrying out maintenance work on the gun, make sure that the unit
has been completely stopped, that all of the push buttons and the main switch are turned
off and that the unit is disconnected from the main power supply. The gun is a
component which works under pressure.
maintenance work be done on component subject to pressure until the pressure has
been completely eliminated.
To remove the mixing block, mixing module and needle, do the following:
1.
Perform the unit Stopping method with the procedure given in the Machine Service
Manual.
2.
Completely close the manual valves of each product by turning them clockwise.
3.
To eliminate the pressure from the gun, press the trigger and project with the gun until the
projection fan begins to narrow.
20/28
No connection must be opened or
Figure .20
1.5 Issue
http://www.novag.eu/
Projection Gun novaG-M
Service Manual
Ref. NR-00018-ENG