To reset the IFT-ECM Control Module:
•
Be aware the appliance may be HOT, use
care in accessing the reset switch.
•
Turn the appliance off at a wall switch location if so
equipped.
•
Wait five minutes to allow possible accummulated gas
to clear.
•
Remove decorative front from appliance.
•
Locate reset switch inside the appliance. See Figure
3.6.
Hold reset switch down for one second and
release. A "beep" will signal module is reset.
Appliances with Wall Switch and Remote
•
Turn wall switch back to "ON" position.
main menu on remote control and restart fireplace.
The fireplace will start as it would under normal
circumstances.
Appliances with Wall Switch Only:
• Turn wall switch back to "ON" position. The fireplace
will ignite as it would under normal circumstances.
Appliances with Remote Only:
• Turn fireplace back on using the main menu on the
remote control. The fireplace will ignite as it would
under normal circumstances.
•
Reinstall decorative front on appliance.
•
If the IFT-ECM re-enters the LOCK-OUT condition
after this procedure, contact your dealer for service.
Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner's Manual • 2458-981 Rev. N • 10/20
Appliance ON/OFF:
Your HEIR fireplace is supplied with a fully functional
remote control. This remote controls:
• ON/OFF Functions
• Flame height adjustments
• Cold Climate Feature
Please refer to the instructions included with the remote
control for more detailed operating instructions.
Optional Heat-Zone
Once the optional Heat-Zone
Go to
fied service technician during the appliance installation
process, follow the instruction supplied with the kit for op-
eration.
• Use the RC400 remote to set the Heat-Zone
MED, LO or OFF. The Fan Speed dynamic icon is
used to change the setting. Refer to the RC400 quick
reference guide in section 6.C.
Gas Kit
®
Kit is installed by a quali-
®
®
to HI,
15