Series 400

In the Series 400 configuration, an Art-Net compatible control console may be connected to one or more Super
Nodes.
Guidelines:
+
When connecting an Art-Net compatible console and multiple Super Nodes, a 100Mb Ethernet switch or hub
must
be used. Standard CAT5e Ethernet cables should be used in this configuration. Refer to the illustration
below.
+
The Series 400 Mode of operation should be used in this configuration. Refer to
+
When using a Node as an Art-Net-to-DMX device, note that the Art-Net/sACN output does not pass data; it only
mirrors the DMX outputs. It is not possible to place the Art-Net/sACN output on the same network as the Art-Net
input.

AC Input/Thru

At rear panel, connect the AC Line Cord Power Cable to the AC IN outlet.
The AC THRU outlet may be used to tap power for additional Super Nodes or Ethernet Switches using the included
PowerCon Jumper Cable. (Do not exceed the 10A maximum total input current to the device.)
AC Line Input

Power Up Procedure

To power up the Super Node unit and set its address:
Step 1. Once the AC input cable is connected and power is applied, the unit will receive power. (It does not have a
power on/off switch.)
SUPER NODE™ USER MANUAL
12
Figure 4: Series 400 Configuration Example
AC Thru to additional devices
Figure 5: Connecting AC Input and Thru Cables