PRG V676 Installation & Operation Manual

Control console
Hide thumbs Also See for V676:

Advertisement

Quick Links

SOFTWARE VERSION 3.6
WWW.PRG.COM
®
V676
CONTROL CONSOLE
INSTALLATION & OPERATION MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the V676 and is the answer not in the manual?

Questions and answers

Summary of Contents for PRG V676

  • Page 1 SOFTWARE VERSION 3.6 WWW.PRG.COM ® V676 CONTROL CONSOLE INSTALLATION & OPERATION MANUAL...
  • Page 2 All other brand names which may be mentioned in this manual are trademarks or registered trademarks of their respective companies. This manual is for informational use only and is subject to change without notice. Please check www.prg.com for the latest version.
  • Page 3 License, is made subject to any restrictions concerning the export of products or technical data from the United States of America which may be imposed upon PRG or you from time to time by the Government of the United States of America. Furthermore, you agree that at no time, either during the term of this License or thereafter, will you knowingly export, directly or indirectly, any United States source technical data acquired from PRG under this License or any direct products of that technical data to any country for which the U.S.
  • Page 4 PRG may suffer, incur, or be subjected to by reason of any claim by a third party due to or arising out of your conduct, your use of the Software, any alleged breach of this License or...
  • Page 5 PRG’s published specifications for the product in effect as of the date of shipment, PRG will repair or replace the product, subject to the terms of this limited warranty. The warranty will be null and void under the following conditions: (a) improper or inadequate maintenance; (b) unauthorized modifications or misuse;...
  • Page 6 DRY LOCATIONS ONLY WARNING! Hazard of electrical shock. Disconnect power before servicing. Service and maintenance should be performed only by qualified personnel as determined by PRG. Refer to service manual before operating or servicing. WARNING! Power supply plug and/or power switch/circuit breaker shall remain readily operable.
  • Page 7 Ne jamais débrancher l'appareil en tirant sur le cordon d'alimentation. Toujours saisir fermement la fiche et tirez-le tout droit hors de la prise. Ne pas utiliser un cordon qui présente des fissures ou des dommages sur toute sa longueur ou aux extrémités. Cordons de rechange peuvent être commandées auprès PRG. Revision History...
  • Page 8 Notes ® V676 CONTROL CONSOLE INSTALLATION & OPERATION MANUAL...
  • Page 9: Table Of Contents

    Touchscreen Operation ............................15 LED Indicators ................................ 16 Setting Preferences Brightness Level ..............................18 For Front Panel and Monitors .......................... 18 For Keyboard ..............................18 Technical Specifications V676 Control Console ............................19 ® V676 CONTROL CONSOLE INSTALLATION & OPERATION MANUAL...
  • Page 10 Notes ® VIII V676 CONTROL CONSOLE INSTALLATION & OPERATION MANUAL...
  • Page 11: Introduction

    PRG Node Plus User Manual (02.9801.0301) PRG Super Node™ User Manual (02.9821.0001) Training Videos Console Training Videos are available on the PRG website. For a list of videos, refer to the following webpage: + http://www.prg.com/console-training-videos/ Customer Service For technical assistance, contact the PRG International Service Center or contact your nearest PRG office. Contact information for all PRG office locations can be found on our website at: www.prg.com...
  • Page 12: Text Conventions And Icons

    Undo Patch Preset Color Beam Time ALT = Speed Manual/ Track/ Track Shift Label Sneak Effect Force SHIFT = Revert Back Copy/ Query/ Delete Group Dynam Step Clear Full Enter Move Help ® V676 CONTROL CONSOLE INSTALLATION & OPERATION MANUAL...
  • Page 13: Product Overview

    PRODUCT OVERVIEW Features The V676 console is a lighting control desk capable of operating automated luminaires, conventional fixtures and media servers. The console supports up to 702 universes when used with PRG Node Plus units. Console Function Capacities: Channels: 4,000 multiple parameter luminaires...
  • Page 14: Included Items

    Figure 1: V676 Components Optional Items Monitors and Channel Select Panel External monitors and/or a Channel Select panel are available from PRG. These are optional items which do not affect the function or capabilities of the console. DMX Processing Module An optional DMX Processing Module - with eight (8) 5-pin DMX512 Outputs, one (1) 5-pin DMX512 Input, and one (1) Ethernet DMX Output - is also available from PRG.
  • Page 15: Desk Layout

    Desk Layout The following illustration shows the major control areas of the V676 console. Encoders / Buttons - Six knobs and associated buttons which can be mapped for control of Rate Encoder - various luminaire parameters. Used to speed up or slow down the Soft Function Buttons - playback of events (cues or effects).
  • Page 16: Console Front And Rear Panels

    Console Front and Rear Panels The following illustrations show the front and rear panels of the V676 console. Note: The drawings in this manual show the optional DMX Processing Module installed, however, your particular console may not have this hardware. Refer to "DMX Processing Module"...
  • Page 17: Installation

    Step 1. Remove all components from shipping container (Figure 4). Step 2. Place console on a sturdy table or other flat surface. AC Power Cable Desk Lamp (2) Console Figure 4: Unpacking the V676 Console Contents ® V676 CONTROL CONSOLE INSTALLATION & OPERATION MANUAL...
  • Page 18 Note: Monitors and/or Channel Select panel are optional. If these components are not included, skip to Step 6. Note: The console supports up to two (2) external monitors (optional). This can be two PRG-provided monitors, two user-provided monitors, or a combination of one each. In any case, only two external monitors should be installed.
  • Page 19 In any case, only two external monitors should be installed. Note that your particular set-up may be different than what is shown here. Figure 6: Connecting Components to V676 Console ® V676 CONTROL CONSOLE INSTALLATION & OPERATION MANUAL...
  • Page 20 Step 7. At rear of console, install desk lamps (Figure 7). Desk Lamp Accessory System Comm Trigger MIDI SMPTE In Seri Enable Thru Aux Ethernet Enable COMPLIENCE Link Link LABEL Line Line/Neut DMX Out INPUT POWER LABEL Figure 7: Installing Desk Lamps ® V676 CONTROL CONSOLE INSTALLATION & OPERATION MANUAL...
  • Page 21 DMX Output Integrated Cable USB (2) Integrated Cable Outputs (2) Outputs (2) Output Convenience Convenience Auxiliary Outlets (2) Outlet Breakers Ethernet Port Figure 8: V676 Console Rear Panel Connections ® V676 CONTROL CONSOLE INSTALLATION & OPERATION MANUAL...
  • Page 22: Display Setup

    Using Standard DVI Monitors If user-supplied DVI monitors are used, these should be connected to the DVI outputs at the rear panel (Figure 9). Installation Guidelines Either PRG-provided touchscreen monitors must be used user-supplied monitors must be installed in their place.
  • Page 23: Basic Operation

    . (During a Front Panel Shutdown, the blue power-down button will slowly flash to indicate that it is in sleep mode.) Power-Down Button Step 3. To restart front panel, press power-down button again. ® V676 CONTROL CONSOLE INSTALLATION & OPERATION MANUAL...
  • Page 24: Restart Vx76 Application

     Step 2. At touchscreen, press Shutdown All . Allow front panel and computer to completely shut down. Step 3. At rear of console, set breaker switch to OFF position. Power-Down Button ® V676 CONTROL CONSOLE INSTALLATION & OPERATION MANUAL...
  • Page 25: Touchscreen Operation

    The console’s external monitors are also touch-enabled. For applicable software screens, the touchscreen interface may be used. Sample Monitor Touchscreen Window Touchscreen Monitors Touch monitor to interface with windows ® V676 CONTROL CONSOLE INSTALLATION & OPERATION MANUAL...
  • Page 26: Led Indicators

    Ethernet DMX Out Link & Activity DMX Out DMX & RDM (8) Console Link & Activity Figure 10: V676 Rear Panel Indicators Indications are as follows: System Comm: Link - Lights green when there is an active link to another Ethernet device.
  • Page 27 DMX - Lights green when DMX512 is being transmitted. RDM - Lights green when an RDM message is received. * These features are available with the optional DMX Processing Module. Refer to "DMX Processing Module" on page 4. ® V676 CONTROL CONSOLE INSTALLATION & OPERATION MANUAL...
  • Page 28: Setting Preferences

    Step 1. At keyboard, press and hold F (function) key. Step 2. While holding down key, press Up/Down buttons until desired brightness level is reached. Step 3. Release key. New brightness level will be set. ® V676 CONTROL CONSOLE INSTALLATION & OPERATION MANUAL...
  • Page 29: Technical Specifications

    PRG Super Node™ - provides up to 16 additional Power Consumption: Console (with displays) - Less than universes 600 watts PRG Series 400 Ethernet Switch - allows 2 or more Physical Specifications: consoles to be linked together CPU: Dual Apple® Mac Mini® Quad-Core Intel Core i7 Outputs: 2.6GHz...
  • Page 30 15.0" (381 mm) 9.75" (248 mm) 11.70" (297 mm) 10.90" (277 mm) 11.5" (292 mm) 46.80" (1,189 mm) 28.60" 24.40" (726 mm) (620 mm) Figure 11: V676 Console Dimensions ® V676 CONTROL CONSOLE INSTALLATION & OPERATION MANUAL...
  • Page 31 V676® Control Console Installation & Operation Manual Version as of: March 22, 2013 PRG part number: 02.9824.0002...
  • Page 32 Production Resource Group, LLC Dallas Office 8617 Ambassador Row, Suite 120 Dallas, Texas 75247 www.prg.com...

Table of Contents