schmersal AZM 161 AS Series Operating Instructions Manual

schmersal AZM 161 AS Series Operating Instructions Manual

Solenoid interlock

Advertisement

Quick Links

Operating instructions
Solenoid interlock
Operating instructions...................... pages 1 to 8
EN
Translation of the original operating instructions
Vous trouverez la version
FR
actuelle du mode d'emploi dans
votre langue nationale oficielle
sur l'Internet, www.schmersal.
net.
U vindt de huidige versie van
NL
de gebruikshandleiding in uw
oficiële landstaal op het Inter-
net, www.schmersal.net.
EU公用語で書かれた最新の
JP
取扱説明書は、インターネッ
(www.schmersal.net)からダウ
ンロードできます。
Content
1

About this document

1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualiied personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
5.1 Mode of operation of the safety outputs. . . . . . . . . . . . . . . . . . . . . .4
5.2 Magnet control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.3 Programming the slave address . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.4 Coniguration of the safety monitor . . . . . . . . . . . . . . . . . . . . . . . . .4
5.6 Read-out of the parameter port . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
7
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
8
8.1 EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Encontrará el manual de
ES
instrucciones actual en su
idioma oicial de la UE en nu-
estra página de Internet www.
schmersal.net.
Il manuale d'istruzioni aggior-
IT
nato nella vostra lingua (lingua
uficiale UE) è scaricabile in
Internet all'indirizzo www.
schmersal.net.
1 About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating inst-
ructions must be available in a legible condition and a complete version
in the vicinity of the device.

1.2 Target group: authorised qualiied personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards to
be complied with as well as other technical speciications for the selec-
tion, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the proper functionality of the entire machinery or plant.
The safety switchgear must be exclusively used in accordance with the
versions listed below or for the applications authorised by the manufac-
turer. Detailed information regarding the range of applications can be
found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating instruc-
tions manual, the country-speciic installation standards as well as all
prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet: www.
schmersal.net.
The information contained in this operating instructions manual is provi-
ded without liability. Subject to technical modiications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.

1.6 Warning about misuse

In case of inadequate or improper use or manipulations of the
safety switchgear, personal hazards or damage to machinery
or plant components cannot be excluded. The relevant requi-
rements of the standard EN 1088 must be observed.
EN
AZM 161 AS
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AZM 161 AS Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal AZM 161 AS Series

  • Page 1 Electrical connection Further technical information can be found in the Schmersal 4.1 General information for electrical connection....3 catalogues or in the online catalogue on the Internet: www.
  • Page 2 Operating instructions Solenoid interlock AZM 161 AS 1.7 Exclusion of liability The user must evaluate and design the safety chain in ac- We shall accept no liability for damages and malfunctions resulting from cordance with the relevant standards and the required safety defective mounting or failure to comply with this operating instructions level.
  • Page 3 Operating instructions Solenoid interlock AZM 161 AS 2.5 Safety classiication (approval under preparation) 2.4 Technical data Standards: EN ISO 13849-1, IEC 61508 Standards: EN 50295, IEC 60947-5-1, EN ISO 13849- If a fault exclusion of a hazardous damage to the 1-channel me- 1, IEC/EN 61508 chanics is authorised and suficient protection against tampering is glass-ibre reinforced thermoplastic, self-...
  • Page 4 Operating instructions Solenoid interlock AZM 161 AS The connection to the AS-Interface system is realised through an M12 Dual-channel dependent connector. The M12 connector is A-coded. The wiring coniguration of Suitable for: AZM 161 Z ST-AS, AZM 161 B ST-AS, AZM 161 BZ ST-AS the M12 connector is deined as follows (to EN 50295): •...
  • Page 5 Operating instructions Solenoid interlock AZM 161 AS AZM 161 Z ST-AS .A. Z-variant, power to lock (magnet-operated locking) System condition Magnet input Channel 1 Channel 2 SaW code AS-i FID Parameter port AS-i D Out: 0 Yellow LED Yellow LED Authorized operation Red LED P0 - P1 - P2 - P3...
  • Page 6 Operating instructions Solenoid interlock AZM 161 AS 6 Set-up and maintenance 6.1 Functional testing The safety function of the safety components must be tested. The following conditions must be previously checked and met: 1. Check the switch enclosure for damage 2.
  • Page 7 Person authorized for the compilation of the technical documentation: Möddinghofe 30 42279 Wuppertal Place and date of issue: Wuppertal, October 22, 2009 Authorised signature Heinz Schmersal Managing Director Note The currently valid declaration of conformity can be downloa- ded from the internet at www.schmersal.net.
  • Page 8 K. A. Schmersal GmbH Industrielle Sicherheitsschaltsysteme Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal Telefon +49 - (0)2 02 - 64 74 - 0 Telefax +49 - (0)2 02 - 64 74 - 1 00 E-Mail: info@schmersal.com...

This manual is also suitable for:

Azm 161 bz st-as aAzm 161 b st-as aAzm 161 z st-asAzm 161 b st-asAzm 161 bz st-as

Table of Contents